Alanine Aminotransferase (ALT/GPT) Activity Assay Kit

SKU: E-BC-K235-M-500

  • $ 40895



Alanine Aminotransferase (ALT/GPT) Activity Assay Kit

SKU # E-BC-K235-M
Detection Instrument Microplate reader (500-520 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms ALT, GPT, Glutamic-pyruvic transaminase
Sample Type Serum, plasma, animal tissue, cells, cell culture supernatant
Sensitivity 0.75 IU/L
Detection Range 0.75-72.3 IU/L
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 80 min
Precision Average inter-assay CV: 9% | Average intra-assay CV: 5.300%
Other instruments required Micropipettor, Vortex mixer, Incubator, Multichannel pipette
Other reagents required Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4)
Storage 2-8℃
Valid period 12 months


Images

X Zhang et al investigate the usage of H2O2 and O2 for cooperative chemodynamic/ starvation cancer therapy. Alanine aminotransferase (ALT) activity in mouse blood was determined using ALT activity assay kit (E-BC-K235-M).

No significant change of ALT activity was observed, the LCFG nanoparticles did not include hepatotoxicity.

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.75-72.3 IU/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human serum 1
Human plasma 1
Porcine serum 1
Rat serum 1
10% Rat brain tissue homogenization 1
10% Rat heart tissue homogenization 1
10% Rat liver tissue homogenization 40-60
10% Rat kidney tissue homogenization 1

 

Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).

 

Detection Principle

ALT catalyze the amino conversion reaction between alanine and α-ketoglutaric acid to produce pyruvic acid and glutamic acid at pH 7.4 and 37℃. Then phenylhydrazine was added to form phenylhydrazone with pyruvic acid. Phenylhydrazone is reddish brown under alkaline conditions. ALT activity can be calculated by measuring the OD values at 510 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Buffer Solution 0.5 mL × 1 vial 0.5 mL × 1 vial 2-8℃, 12 months
Reagent 2 2 mmol/L Sodium
Pyruvate
0.5 mL × 1 vial 0.5 mL × 1 vial 2-8℃, 12 months
Reagent 3 Substrate Solution 2.5 mL × 1 vial 5 mL × 1 vial 2-8℃, 12 months
Reagent 4 Chromogenic Agent 2.5 mL × 1 vial 5 mL × 1 vial 2-8°C, 12 months, shading light
Reagent 5 Alkali Reagent 2.5 mL × 1 vial 5 mL × 1 vial 2-8℃, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (IU/L) 3.50 26.50 52.60
%CV 5.7 5.2 5.0


Inter-assay Precision

Three human serum samples were assayed 17 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (IU/L) 3.50 26.50 52.60
%CV 8.4 9.2 9.4


Sensitivity

The analytical sensitivity of the assay is 0.75 IU/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Carmen Unit 0 28 57 97 150 200
Average OD 0.247 0.324 0.384 0.436 0.489 0.537
Absoluted OD 0 0.078 0.137 0.190 0.242 0.290