Citrate Synthase(CS) Activity Assay Kit

SKU: E-BC-K178-M-96

  • $ 38295



Citrate Synthase(CS) Activity Assay Kit

SKU # E-BC-K178-M
Detection Instrument Microplate reader (402-422 nm, optimum wavelength: 412 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms CS
Sample Type Animal, plant tissue and cell
Sensitivity 2.09 U/L
Detection Range 2.09–110 U/L
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 30 min
Precision Average inter-assay CV: 7.900% | Average intra-assay CV: 5%
Other instruments required Incubator, Centrifuge
Storage -20℃
Valid period 12 months


Detection Principle

Citrate synthetase (CS) catalyzes acetyl-CoA and oxaloacetate to produce limonyl-CoA, which can further produce CoA. The yellow product generated by this reaction has a characteristic absorption peak at 412 nm. The activity of CS can be calculated by measuring the change of absorbance value at 412 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Extracting Solution 50 mL × 1 vial 50 mL × 2 vials -20°C, 12 months
Reagent 2 Buffer Solution 9 mL × 1 vial 18 mL × 1 vial -20°C, 12 months
Reagent 3 Substrate 1.8 mL × 1 vial 1.8 mL × 2 vials -20°C, 12 months
shading light
Reagent 4 Chromogenic Agent 1.6 mL × 1 vial 1.6 mL × 2 vials -20°C, 12 months
shading light
Reagent 5 Standard Powder × 1 vial Powder × 2 vials -20°C, 12 months
shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 10.5 55.6 87.6
%CV 3.9 5.6 5.5


Inter-assay Precision

Three human serum samples were assayed 17 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 10.5 55.6 87.6
%CV 6.4 7.5 9.8

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 104%.

Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.2 0.4 0.8
Observed Conc. (mmol/L) 0.2 0.4 0.9
Recovery rate (%) 98 106 108

 

Sensitivity

The analytical sensitivity of the assay is 2.09 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (μg/L) 0.0 0.2 0.3 0.4 0.6 0.8 0.9 1
Average OD 0.151 0.209 0.246 0.287 0.363 0.439 0.476 0.512
Absoluted OD 0.000 0.058 0.095 0.136 0.212 0.288 0.325 0.361