Fluoride Resistant Acid Phosphatase (FRAP) Activity Assay Kit
SKU: E-BC-K872-M-96
Fluoride Resistant Acid Phosphatase (FRAP) Activity Assay Kit
SKU # | E-BC-K872-M |
Detection Instrument | Microplate reader (390-415 nm, optimum wavelength: 405 nm) |
Detection method: | Colorimetric method |
Product Details
Properties
Synonyms | FRAP |
Sample type | Serum (plasma), cells and animal tissue samples |
Sensitivity | 0.61 U/L |
Detection range | 0.61 - 49.37 U/L |
Detection method | Colorimetric method |
Assay type | Enzyme Activity |
Assay time | 25 min |
Precision | Average inter-assay CV: 8% | Average intra-assay CV: 3.600% |
Other instruments required | Incubator(37℃) |
Other reagents required | Double distilled water, Normal saline (0.9% NaCl) |
Storage | -20℃ |
Valid period | 12 months |
Dilution of Sample
The recommended dilution factor for different samples is as follows (for reference only):
Sample type | Dilution factor |
10% Mouse liver tissue homogenate | 3-7 |
10% Mouse kidney tissue homogenate | 3-7 |
10% Mouse heart tissue homogenate | 3-7 |
10% Mouse lung tissue homogenate | 3-7 |
Rat plasma | 5-7 |
Human serum | 1-3 |
Bovine serum | 1-3 |
1×106 HL-60 cell | 1 |
1×106 293T cell | 1 |
Note: The diluent is normal saline (0.9% NaCl). For the dilution of other sample types, please do pretest to confirm the dilution factor.
Detection Principle
Fluoride resistant acid phosphatase (FRAP) is not inhibited by fluoride ions. It catalyzes the substrate to produce p-nitrophenol, which has a maximum absorption peak at 405 nm. The activity of FRAP can be calculated by measuring the OD value at 405 nm.
Kit Components & Storage
Item | Component | Size (96 T) | Storage |
Reagent 1 | Buffer Solution | 20 mL × 1 vial | -20°C, 12 months |
Reagent 2 | Fluoride Ion Solution | 0.5 mL × 1 vial | -20°C, 12 months |
Reagent 3 | Substrate Solution | 1 mL × 1 vial | -20°C, 12 months, shading light |
Reagent 4 | Chromogenic Agent | 14 mL × 1 vial | -20°C, 12 months |
Reagent 5 | 10 mmol/L Standard Solution | 1 mL ×1 vial | -20°C, 12 months, shading light |
Microplate | 96 wells | No requirement | |
Plate Sealer | 2 pieces |
Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.
Technical Data:
Parameter:
Intra-assay Precision
Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)
Parameters | Sample 1 | Sample 2 | Sample 3 |
Mean (U/L) | 3.50 | 18.40 | 36.70 |
%CV | 3.8 | 3.5 | 3.5 |
Inter-assay Precision
Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.
Parameters | Sample 1 | Sample 2 | Sample 3 |
Mean (U/L) | 3.50 | 18.40 | 36.70 |
%CV | 7.6 | 8.2 | 8.2 |
Recovery
Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 102%.
Standard 1 | Standard 2 | Standard 3 | |
Expected Conc. (mmol/L) | 0.13 | 0.25 | 0.37 |
Observed Conc. (mmol/L) | 0.1 | 0.3 | 0.4 |
Recovery rate(%) | 101 | 104 | 101 |
Sensitivity
The analytical sensitivity of the assay is 0.61 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.
Standard Curve
As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:
Concentration (mmol/L) | 0 | 0.1 | 0.15 | 0.2 | 0.3 | 0.35 | 0.4 | 0.5 |
Average OD | 0.054 | 0.148 | 0.201 | 0.254 | 0.351 | 0.406 | 0.455 | 0.544 |
Absoluted OD | 0 | 0.094 | 0.147 | 0.2 | 0.297 | 0.352 | 0.401 | 0.490 |