Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

ICP-MS Testing Service, ICP-MS Analytical Service– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

ICP-MS Testing Service, ICP-MS Analytical Service

ICP-MS Testing Service, ICP-MS Analytical Service

SKU: ICPMS001

  • $ 8095



Overview

Our ICP-MS Testing/Analytical Service offers accurate and precise results, ideal for a range of laboratory and research applications. Delivering fast and reliable results with a low detection limit, our service is ideal for elemental quantitation using a cutting-edge ICP-MS machine.

Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) is capable of detecting metals at very low concentrations, as low as 1 ppq (one part per quadrillion). An ICP-MS unit ionizes the sample using inductively coupled plasma. Plasma in this case is created by heating argon gas to 10,000°C causing the argon gas to increase in its electrical conductive properties and eventually transforming the argon from a gas state into the plasma state. Once ionized the molecules that make up the sample are separated based on it mass-to-charge ratio and quantified using a mass spectrometer.

Sample requirements

Pre-treated Solution Samples:

  • a. Transparent and Clear Solution: The solution must be stable with no precipitate. For colored solutions, confirm whether they are ionic solutions; if unsure, perform acid treatment before analysis to avoid damaging the instrument. Provide 5-10 ml of sample, preferably neutral to slightly acidic, with an acid concentration below 5%. Solutions containing hydrofluoric acid (HF) cannot be tested directly—ensure F ions are fully evaporated, and pre-digested samples must be diluted.
  • b. Organic Solutions: Carbon-containing solutions cannot be tested directly and must be digested with nitric acid to eliminate carbon.
  • c. Free of Impurities: Samples must not contain any insoluble impurities or organic matter. It is recommended to filter the solution through a 0.45 μm membrane. Secure the container lid tightly and seal it with parafilm to prevent leakage.

Untreated Liquid Samples:

  • a. Routine Water Samples: Provide at least 50 ml. For custom or other liquid samples, provide at least 10 ml and label the sample composition to aid in selecting the appropriate digestion method.
  • b. Secure the container: Ensure the container lid is tightly closed and sealed with parafilm to prevent leakage.

Untreated Solid Samples:

  • a. Powder Samples: Provide at least 100 mg of sample, pre-ground into a fine powder if possible, and sieved through a 200-mesh sieve if conditions allow. For microwave digestion, provide at least 200 mg.
  • b. Limited Quantity Samples: Wrap small quantities of solid samples in weighing paper and place them in a tube.

Recovery Notice:
This is a destructive testing method. Samples used during analysis cannot be recovered, and only any remaining sample (if available) can be returned.

MSE Supplies offers professional ICP-OES Testing Service using PerkinElmer Optima 5300DV, Optima 8300, ICP 2100 or similar instrument.

Analytical Service Minimum order requirement: $250 per order. A $200 handling fee will be applied if order is below $250.

MSE Analytical Services offer professional ICP-MS Testing Service for fast identification and detection of trace metals content in chemical samples.

* Note: Data analysis service is not included in the list prices.

Highlights: High Quality Data, Competitive Pricing, Technical Support by Scientists.

Please contact sales@msesupplies.com for additional information and instructions on our Analytical Services program. Confirmation of the sample(s) requirements, SDS sheets and additional information is needed prior to processing the Analytical Service order. 

***Please do not ship any samples without authorization from MSE Supplies***