α-Ketoglutarate (α-KG) Fluorometric Assay Kit

SKU: E-BC-F047-96

  • $ 44295



α-Ketoglutarate (α-KG) Fluorometric Assay Kit

SKU # E-BC-F047
Detection Instrument Fluorescence microplate reader (Ex/Em=535 nm/587 nm)
Detection Method Fluorescence method


Product Details

Properties

Synonyms α-KG
Sample Type Serum, plasma, urine, animal tissue, cell sample
Sensitivity 0.60 μmol/L
Detection Range 0.60-100 μmol/L
Detection Method Fluorescence method
Assay Time 35 min
Precision Inter-assay CV: 4% | intra-assay CV: 2%
Other Reagents Required Normal saline (0.9% NaCl)
Storage This product can be stored at -20°C for 12 months with shading light.
Valid period 12 months

 

Dilution Of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Rat kidney tissue homogenate 1
10% Rat lung tissue homogenate 1
10% Porcine heart tissue homogenate 1
10% Rat brain tissue homogenate 1
10% Mouse liver tissue homogenate 1
10^6 Jurkat cell 1
Human serum 1
Rat serum 2-3


The diluent is normal saline (0.9% NaCl). For the dilution of other sample types, please do pretest to confirm the dilution factor.


Detection Principle

α-Ketoglutaric acid and alanine can be combined with fluorescent probe products under the action of a series of enzymes. The content of α-ketoglutaric acid in samples can be determined by measuring the fluorescence value.

 

Kit Components & Storage

Item Component Size 1(48 T) Size (96 T) Storage
Reagent 1 Buffer Solution 13 mL ×1 vial 26 mL ×1 vial -20℃, 12 months
Reagent 2 Substrate Powder × 1 vial Powder × 2 vials -20℃, 12 months
Reagent 3 Enzyme Reagent Powder × 1 vial Powder × 2 vials -20℃, 12 months shading light
Reagent 4 Probe 1.2 mL × 1 vial 2.4 mL × 1 vial -20℃, 12 months shading light
Reagent 5 Standard Powder × 2 vials Powder × 2 vials -20℃, 12 months shading light
Black Microplate 96 wells No requirement
Plate Sealer 2 pieces


Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents


    Technical Data:

    Parameter:

    Intra-assay Precision

    Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

    Parameters Sample 1 Sample 2 Sample 3
    Mean (μmol/L) 1.00 25.00 50.00
    %CV 2.3 1.9 1.8

     

    Inter-assay Precision 

    Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

    Parameters Sample 1 Sample 2 Sample 3
    Mean (μmol/L) 1.00 25.00 50.00
    %CV 4.5 4.1 3.4


    Recovery

    Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 99%.


    Standard 1 Standard 2 Standard 3
    Expected Conc. (μmol/L) 15 45 70
    Observed Conc. (μmol/L) 15.2 44.6 67.9
    Recovery rate (%) 101 99 97

     

    Sensitivity

    The analytical sensitivity of the assay is 0.60 μmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.


    Standard Curve:

    As the fluorescence value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

    Concentration (μmol/L) 0 10 20 30 50 60 80 100
    Fluorescence value 547 1406 2078 3267 5050 6140 7629 9415
    568 1369 2406 3370 5271 6145 8164 9746
    Average fluorescence value 557 1388 2242 3318 5161 6143 7897 9581
    Absoluted fluorescence value 0 830 1685 2761 4603 5585 7339 9023