Monkeypox Virus (MPXV) IgG ELISA Kit
SKU: E-EL-E620
Monkeypox Virus (MPXV) IgG ELISA Kit
Product Details
Properties
Assay Type | Competitive-ELISA |
Format | 96T |
Assay time | 1.5h |
Sample type | serum and plasma |
Storage | 2-8℃ |
Application | This ELISA kit applies to the in vitro determination of in serum or plasma. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Test Principle
This ELISA kit uses Indirect-ELISA as the method to qualitatively detect the
Monkeypox Virus (MPXV) IgG in the sample. The micro ELISA plate provided in
this kit is pre- coated with purified MPXV antigen, after adding samples to wells, the
MPXV IgG in the samples will combine with the pre-coated MPXV antigen. After
washing completely, add Horseradish Peroxidase (HRP) conjugated goat anti human
IgG to develop the antigen- antibody-HRP conjugated secondary antibody complex.
Free components are washed away, then the substrate solution is added to each well.
Only those wells that contain MPXV IgG and HRP conjugated anti-human IgG will
appear blue in color. The enzyme- substrate reaction is terminated by the addition of
stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ± 2 nm. Compared with the CUT OFF value to judge whether MPXV IgG exists in the tested samples or not.
Kit Components and Storage
The unopened kit can be stable for 6 months at 2-8℃. After opening the kit, keep
the reagents according to the conditions below.
Item | Specifications | Storage |
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips | 2-8℃, 6 months |
48T: 8 wells ×6 strips | ||
Positive Control | 96T: 2 vials | |
48T: 1 vial | ||
Negative Control | 96T: 2 vials | |
48T: 1 vial | ||
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL | -20℃ (Protect from light), 6 months |
48T: 1 vial, 60 μL | ||
Sample & Control Diluent | 2 vial, 20 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer(25×) | 1 vial, 30 mL | |
Stop Solution | 1 vial, 10 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) , 6 months |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Assay Procedures
1. Add 100µL of controls and samples to the appropriate wells. Incubate for 45 min at 37°C. |
|
2. Aspirate and wash the plate for 3 times. |
|
3. Add 100µL of HRP Conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times. |
|
4. Add 90µL of Substrate Reagent. Incubate for about 15 min at 37°C. |
|
5. Add 50µL of Stop Solution. |
|
6. Read the plate at 450nm immediately. Calculation of the results. |