MSE PRO Biological Safety Cabinet (Class II, Type A2 BSC)
SKU: LS0226
MSE PRO™ Biological Safety Cabinet (Class II, Type A2 BSC)
Class II Biological Safety Cabinets (BSC) ensure a high level of protection for the operator, product and environment, minimizing hazards inherent to working with biosafety levels 1, 2 and 3 agents and maintaining a sterile environment for your needs.
1300 Series: 1300mm (51.2in/4.3ft) width of Cabinet
1500 Series: 1500mm (59in/4.9ft) width of Cabinet
1800 Series: 1800mm (70.9in/5.9ft) width of Cabinet
Features:
- Includes BSC, Power Cord, Fuses (2 ea.) and Product Manual
- 7-in touch screen interface that displays fan operations, front window state, filter, sterilization lamp life percentage, alarm status, and operation logs
- High efficiency and energy saving
- Pressure sensor monitors airflow based on filter resistance
- High quality steel and lacquered in ivory
- Comfortable working area
- Ergonomic design
- Easy to clean
Certification: EN 12469
Specifications
SKU # | LS0226 | LS0227 | LS0228 |
Series |
1300 Series |
1500 Series |
1800 Series |
External dimensions WxDxH (mm) | 1300x807x2240 | 1500x807x2240 | 1800x810x2207 |
Internal dimensions WxDxH (mm) | 1180x580x798 | 1380x580x798 | 1680x580x798 |
Support Base WxDxH (w/ Wheels, mm) | 1285x710x680 | 1485x710x670 | 1800x710x645 |
Weight (kg) | 265 | 312 | 375 |
Power Supply | 110V, 60Hz |
110V, 60Hz |
110V, 60Hz |
Filtration Efficiency | >99.9995%, @0.12μm | >99.9995%, @0.12μm | >99.9995%, @0.12μm |
Air Supply and Exhaust Filters | ULPA Filters | ULPA Filters | ULPA Filters |
Air Cleanliness | ISO 4 Class | ISO 4 Class | ISO 4 Class |
Execution Standards |
YY0569(GB 4793.1 GB/T 18268.1) |
YY0569(GB 4793.1 GB/T 18268.1) |
YY0569(GB 4793.1 GB/T 18268.1) |
Down Flow Velocity (m/s) | 0.35 | 0.35 | 0.35 |
Inflow Velocity (m/s) | 0.55 | 0.55 | 0.55 |
Noise Level (dB) | <65 d | <65 d | <65 d |
Vibration | <5μm (center of tabletop) | <5μm (center of tabletop) | <5μm (center of tabletop) |
Personnel Protection | A.Total colony in impaction sampler <10CFU./time B. Total colony in slot sampler <5CFU./time |
A.Total colony in impaction sampler <10CFU./time B. Total colony in slot sampler <5CFU./time |
A.Total colony in impaction sampler <10CFU./time B. Total colony in slot sampler <5CFU./time |
Product Protection | Total colony in culture dish <5CFU./time | Total colony in culture dish <5CFU./time | Total colony in culture dish <5CFU./time |
Cross-Contamination Protection | Total colony in culture dish <2CFU./time | Total colony in culture dish <2CFU./time | Total colony in culture dish <2CFU./time |
Max Consumption (w/ Spare Socket, kW) |
1.65 | 1.65 | 1.65 |
Rated Power (w/o Spare Socket) | 0.33 | 0.33 | 0.33 |
Size and Qty. of Light | 18Wx1 | 18Wx1 | 18Wx1 |
Size and Qty. of UV Light | 20Wx1 | 20Wx1 | 20Wx1 |
Lumin. | ≥900LX | ≥900LX | ≥900LX |
Cabinet Materials | High-grade steel and lacquered in ivory | High-grade steel and lacquered in ivory | High-grade steel and lacquered in ivory |
Working Area Materials | SS304 fully finished | SS304 fully finished | SS304 fully finished |
Air Direction | Top out | Top out | Top out |
Air Quality | ISO 4 in accordance with ISO CD 14644-1: 353 part. ≥0.5 μm/m3; 10000 part. ≥0.1 μm/ m3 |