MSE PRO Gas Chromatography System (LCD Touch Screen), Model 2
SKU: MA2645
MSE PRO™ Gas Chromatography System (LCD Touch Screen), Model 2
Overview
The MSE PRO Gas Chromatography System (LCD Touch Screen), Model 2 is a high-performance, fully automatic gas chromatograph designed for versatile applications. It offers high stability, reliability, and ease of use, making it suitable for fields such as environmental analysis, toxicology, clinical research, food fermentation, petroleum processing, geology, organic synthesis, and health quarantine.
Key Features
Precision Temperature Control
- Microcomputer system with ±0.05°C accuracy, six independent zones, and a maximum temperature of 420°C.
- Safety ensured by over-temperature protection and limit temperature settings.
User-Friendly Interface
- A large touch screen enhances visibility and simplifies operation.
Flexible Injection Options
- Supports dual-channel packed-column injectors or capillary split/splitless injectors for double-column detection.
Versatile Detector Configurations
- Compatible with six detectors (FID, TCD, ECD, FPD, NPD, QMS).
- Up to three detectors can be installed simultaneously (TCD required), with additional customization options.
Digital Gas Circuit Control
- Fully digital system for adjusting flow rate, pressure, and split ratio via the touch screen.
Advanced Column Oven
- Accommodates capillary and dual packed columns.
- Features rapid heating/cooling with an auto-open back door and supports 20-stage temperature programming.
Integrated Instrument Control
- Built-in device collects chromatographic signals and manages real-time control (temperature, detectors, and gas flow) through specialized software.
Comprehensive Data Processing
- Dual-channel (expandable) high-speed data acquisition, with features like baseline correction, five quantification methods, and automated/manual parameter settings for detailed reporting.
Specification
Model | MSE PRO GC Model 2 | |
Description | EPC(electronic pneumatic control) 7 inch touch screen display | |
Sample Introduction System | sample injector and evaporation chamber | |
Column Oven | Temperature range | Ambient temperature +7℃ ~ 400℃ (in 1℃incremen |
Temperature accuracy | ± 0.02℃ | |
Cooling time | 350℃〜100℃≤3min, 400℃ to 50℃ in 8-10 min at 25℃ ambient |
|
Programmed temperature setting | 0.1℃~40℃/min (in 1℃ increment) | |
Program ramps | 20 ramps in total (10 ramps available with control workstation |
|
Size (L*W*H) | 284*280*241mm(inside)340*345*281mm(outside) | |
Flame Ionization Detector (FID) | Detection limit | ≤8×10- 12 g/s (n-hexadecane) |
Thermal Conductivity Detector(TCD) | Drift | ≤1.5×10- 13 A/h |
Noise | ≤3×10- 14 A | |
Linearity range | ≥106 | |
Flame Photometric Detector(FPD) | Detection limit | ≤8×10- 13 g/s(P) ; ≤8×10- 11 g/s(S) |
Drift | ≤2×10- 11 A/30min | |
Baseline noise | ≤5×10- 12 A | |
Nitrogen-Phosphorus Detector(NPD) | Detection limit | ≤5×10- 13 g/s(P) ( Malathion); ≤5×10- 12 g/s(N)( Azobenzene) |