MSE PRO Gas Chromatography System, Model 3

SKU: MA2665

  • $ 8,56995



MSE PRO™ Gas Chromatography System, Model 3

    Overview

    The next-generation MSE PRO Gas Chromatography System, Model 3 sets a benchmark comparable to leading international brands. It features advanced technologies such as electronic flow control, microfluidic plate management, and high-precision independent temperature control, delivering exceptional analytical performance and reliable stability to meet users' demanding requirements. 

    The MSE PRO GC Model 3 is equipped with intelligent features like self-diagnosis, leak detection, carrier gas conservation, and automated reminders, enabling you to monitor instrument status and address issues with ease. It is compatible with various pretreatment devices, including solid-phase microextraction, headspace sampling, and liquid samplers, offering expanded application possibilities tailored to your needs.

    Key Features

    • Ultra-Stable Liquid Injection Port
    • High-Precision Electronic Pressure Controller (EPC)
    • World-Class Column Oven
    • Intuitive and User-Friendly Workstation Software
    • Exceptional Human-Computer Interaction Experience
    • Supports Multiple Detector Options (Up to Four Simultaneously)

    Specification

    1. System Performance
    Peak area repeatability < 0.5% RSD;
    Retention time repeatability < 0.008% RSD;
    2 injection ports, 4 detectors and 3 detector signals can be installed at the same time. All inlet, detector and auxiliary gas path are controlled by electronic flow path, support pressure and temperature compensation;
    *The instrument can be upgraded to gas chromatography-single quadrupole mass spectrometer and gas chromatography-triple quadrupole mass spectrometer of the same brand as gas chromatograph.
    The detector uses electronic digital data output;
    ≥6 electronic flow control modules can be installed at the same time to provide ≥18 gas path control;
    There are 4 separate heating zones (excluding column oven).
    2. Environmental Conditions
    Ambient operating temperature range 5℃~35℃ or wider;
    Ambient working humidity range 5%-95%RH or wider;
    Power supply requirements 220 V±10%, 50 Hz±10%;
    3. Column Oven
    Temperature control range room temperature +4℃~450℃ or wider;
    Temperature setting accuracy ≤0.1℃;
    Temperature control accuracy ≤0.01℃
    *Program level 31 level /32 platform, can achieve program temperature and program cooling;
    Maximum heating rate ≥120 ℃/min;
    Cooling rate from 450℃ to 50℃ (room temperature 20℃) ≤6 min;
    The ambient temperature changes by 1℃, and the average temperature of column temperature chamber changes by < 0.01℃.
    4. Electronic Pressure Flow Controller (EPC)
    *Ruby damper;
    Pressure control accuracy ≤± 0.001psi;
    The pressure unit can be psi, kpa, bar;
    Gas path control mode constant pressure, constant current, program boost and program lift steps ≥4 steps, can calculate the column average linear velocity;
    Pressure control range 0~100 psi or wider;
    Flow monitoring range Nitrogen 0~500 mL/min or wider, hydrogen or helium 0~1000 mL/min or wider.
    5. Split/splitless Inlet
    Maximum operating temperature ≥450℃;
    Temperature setting accuracy ≤0.1℃;
    Maximum split ratio ≥ 1:12,500;
    The sample inlet has automatic leak detection function;
    The injection modes can be split, splitless, pulse split, pulse splitless, etc.
    Applicable to all capillary columns (inner diameter 0.1mm ~ 0.53mm);
    The injector spacer and split plate can be replaced by manual maintenance without tools.
    6. Detector
    Hydrogen Flame Ionization Detector (FID)
    Maximum operating temperature ≥450℃;
    Detection limit <5×10-12 g C/s;
    Linear range ≥107;
    Signal acquisition frequency ≥200 Hz;
    With automatic ignition function and flameout protection function;
    Hydrogen leakage protection.
    Flame Photometric Detector (FPD)
    Maximum operating temperature ≥350℃;
    Detection limit <9×10-14 g/s (P), 5×10-12 g/s (S);
    Linear range ≥104 (P), ≥103 (S);
    Signal acquisition frequency ≥200 Hz;
    With automatic ignition function and flameout protection function;
    With automatic ignition function and flameout protection function;
    Hydrogen leakage protection function.
    Electron Capture Detector (ECD)
    Maximum operating temperature ≥350℃;
    Detection limit <3.8×10-14 g/ml;
    Signal acquisition frequency ≥200 Hz.
    Thermal Conductivity Detector (TCD)  
    Maximum operating temperature ≥350℃;
    Detection limit:   < 8.7×10-6 g/ml;
    Linear range ≥104;
    Signal acquisition frequency ≥200 Hz.
    7. Assistant EPC Module
    Pressure control range 0~100 psi or wider;
    Pressure control accuracy ≤± 0.001psi.
    8. Host Display
    *≥8 inches high resolution full color full touch capacitive screen, built-in intelligent operating system;
    The host control software is customized based on Android system, graphical UI, and intelligent functions such as self-diagnosis and reminder, self-leak detection, and carrier gas self-saving.
    9. Workstation Software
    *Independent research and development software, according to user needs to develop special software;
    Collection software and analysis software can be installed separately and work independently. The workstation software occupies less than 1 GB of memory.
    The analysis software has the functions of data screening, batch processing, automatic calculation of statistical data, and drawing trend chart.