MSE PRO Gas Chromatography-Triple Quadrupole Mass Spectrometry (GC-MS/MS) System
SKU: MA2685
To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.
MSE PRO™ Gas Chromatography-Triple Quadrupole Mass Spectrometry (GC-MS/MS) System
Overview
The MSE PRO Gas Chromatography-Triple Quadrupole Mass Spectrometry (GC-MS/MS) System combines the advanced capabilities of gas chromatography and mass spectrometry. It offers excellent sensitivity, selectivity, stability, and robust anti interference performance. This makes it ideal for high-sensitivity qualitative and quantitative analysis of trace pesticides and veterinary drugs in complex matrices.
Key Features
- EI Ion Source
- Collision Cell with Axial Acceleration
- Tandem Triple Quadrupole (QQQ) Mass Analyzer
- Pure Molybdenum Quadrupole Mass Spectrometer
- Intelligent MRM (Multiple Reaction Monitoring)
- Exceptional Sensitivity
Specification
Gas Chromatograph | |
1. Column oven | |
Maximum service temperature | 450 ℃ |
Heating rate | 120 ℃/min at maximum, typically 50 ℃/min; The temperature rise program in 32 steps and 33 stages and temperature decline program is supported, with the reproducibility better than 0.5%; 5min are required for cooling from 450 ℃ to 50 ℃; |
Temperature control accuracy | within ± 0.1 ℃ |
Holds up to 3 capillary columns | |
2. Split/splitless injection ports | |
Maximum service temperature | 450 ℃ |
Gas circuit system | The programmable electronic gas circuit control is adopted to provide various control modes such as constant pressure, constant flow, programmed boost and programmed upflow |
Flow control | 0-500 mL/min (N2); 0-1,000mL/min (He, H2) |
Pressure control | 0-100.00 psi (689.5 kpa) |
Control accuracy | ±0.001 psi, capable of realizing sample injection under pulse pressure. |
Operation mode | split or spliteless |
3. Programmable electronic gas circuit control | |
Modular design is adopted, which can support up to 18 channels of electronic pressure and flow control; | |
The flow, pressure, linear speed and split ratio of the injection port are set directly through the workstation software or touch screen | |
It has the function of automatic atmospheric pressure and temperature compensation. | |
4. Automatic sample injector | |
Support 16 bit or 110 bit automatic sample injector | |
Injection volume | 0.1μL-250μL (16 bit) or 500 μL (110 bits) |
Sampling accuracy | ± 0.01% |
Injection precision | RSD < 0.5% |
Mass spectrometry system | |
1. EI ion source | double filament, with 10-300eV ionization energy and 150 ℃-350 ℃ of heating temperature. |
2. Sample injection interface | Non-cold point heat tracing technology is adopted for the MS/MS interface, and the interface temperature is 50-400 ℃, so as to ensure the efficient transmission of GC-MS/MS samples. |
3. Ion optical system | |
90° deflection is adopted to effectively filter the unionized neutral particles, so as to reduce the background noise and avoid the pollution to the detector. | |
No redundant transmission pole is set in the ion transmission system, and the ions can directly enter Quadrupole to avoid ion loss during transmission. | |
4. Mass analysis system | |
Mass analyzer | Triple quadrupole mass analyzer. |
Quadrupole | Gold-plated quadrupole made of high precision pure Mo material is used, and the material can realize the best stability through deactivation; Cleanable pre- and post- quadrupoles are set to eliminate the organic deposits; and the best mass axis stability can be ensured without heating. |
Collision cell | Hexapole axial acceleration design is adopted, capable of effectively eliminating the interference of ion pair and ensuring the high-throughput analysis capability. High-purity nitrogen is adopted as the collision gas (with the purity ≥ 99.999%). |
Resolution | 0.4-3.0amu, adjustable. |
Mass stability | < ± 0.1amu/24 hours. |
Scanning speed | up to 20,000 amu/s. |
Number of MRM channels | 100 channels/s |
Mass range m/z | EI, 5 -1,100amu; |
Sensitivity | EI, MRM mode: 100fg/uL OFN of 1uL, ≥ 15000:1 |
Full scan, selected ion monitoring (SIM), product ion scan, precursor ion scan, neutral loss scan, multiple reaction monitoring (MRM), etc. | |
5. Detector | |
90°off-axis electron multiplier technology, without any positive and negative ion discrimination effect, which has long service life, capable of ensuring the long-term data stability. | |
Pulse-counting detector, to ensure the data reproducibility of low limit of detection. | |
6. Vacuum system | Mechanical pump and dual inlet turbomolecular pump at 250 + 450L/s. A differential pumping system is formed between the ion transmission area and mass analysis area, functioning for automatic power-off protection. |
7. Workstation software | |
Basic features of software system | Windows 10 operating system. The software can control the gas chromatograph, liquid chromatograph and mass spectrometer, with built-in data processing and report editing functions. Besides, the software can realize the function configuration and condition optimization of the instrument automatically, the atomatic quantification, the mass spectrometry data analysis, and the establishment and retrieval of spectral database. |
The system has the functions of automatic correction and instrument condition monitoring. | |
The GC-MS/MS operation software can be installed on the personal computer, and used for the offline processing of sample analysis data and report generation. |
Accessory System
- Computer System: Brand-name computer with a mainstream configuration, including 4GB of memory and a 1TB hard drive.
- AC Stabilized Power Supply: 15KVA capacity, input voltage range of 140V–300V, and output voltage of 220V ± 1%.
- Laser Printer: Model 6018L, black-and-white laser printer.
- Mechanical Pump: Pumping speed of 65 m³/h, powered by a 220V supply with an 800W capacity.
Optional Parts
SKU# | Product name | Price |
MA2686 | 19-vial liquid automatic sampler | 5839.95 |
MA2687 | 150-vial sample tray | 7499.95 |
MA2688 | 150-vial liquid automatic sampler | 13339.95 |