MSE PRO Ion Chromatography System Model 2
SKU: MA2607
MSE PRO™ Ion Chromatography System Model 2
Overview
The MSE PRO Ion Chromatograph Model 2 features a new modular design, offering high stability for ion chromatography. It is equipped with a conductivity detector and integrates seamlessly with a robust chromatography workstation and precision circuit control system. Additionally, the MSE PRO Ion Chromatograph Model 2 can be configured with a UV-Vis detector, enabling applications in various fields such as environmental analysis, food safety, chemical research, geology, and more. It is capable of analyzing conventional cations and anions, sugars, amino acids, small organic acids, cyanides, and other compounds.
Features
- Auto-range conductivity detector. Greater detection range, better precise analysis
- Built-in circulating 3D constant temperature technology. Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data
- The world’s leading full-range series of ion chromatograph columns High efficiency, large capacity of the columns for detecting ions of varied compositions
- Self-Regenerating electrolytic micro-membrane Suppressor. High pressure resistance, small dead volume, highly responsive to signals
- Able to detect anions and cations at the ppb level.
- Work across a variety of detectors, to expand the scope of applications of ion chromatography.
Specifications
Flow Path | PEEK material | Chemically inert, metal-free PEEK flow paths, compatible with aqueous eluents of pH 0-14 and reversed-phase solvents |
Pump | Type | High-pressure and low-pulse two-piston tandem advection pump |
Maximum Pressure | 42 MPa | |
Flow Rate Range | 0.001~9.999 mL/min | |
Pressure Ripple | <=0.5% | |
Flow Precision | <=0.1% | |
Flow Accuracy | <=0.1% | |
External Diameter of the Tube | 1/16" | |
Valve | Contact Material of the Rotor | PEEK |
Control Mode | By Stepper Motor | |
Power Supply | 24V (DC) | |
Column Heater | Operating Temperature Range | Ambient temperature +5 to 60°C |
Controlling Temperature Accuracy | ±0.1°C | |
Temperature Stability | <=0.1°C/h | |
Columns Supported | 2, 3, 4, and 5 mm i.d., Maximum length 250 mm analytical column with 50 mm guard column |
|
Conductivity Detector | Type | Auto-range conductivity detector |
Cell Volume | <=0.8µL | |
Detection Range | 0~45000µS/cm | |
Resolution | <=0.0020nS/cm | |
Output Voltage | -6000~+6000mv (adjustable) | |
Electronic Noise | 0.02nS | |
Baseline Noise | <=0.001µS/cm | |
Baseline Drift | <=0.01µS | |
Operating Temperature Range | Ambient +5°C~60°C | |
Controlling Temperature Accuracy | ±0.01°C | |
Temperature Compensation | 1.7%/°C | |
Maximum Pressure | 10.0MPa | |
Instrument Linearity | ≥0.999 | |
Quantitative Repeatability | ≤0.5% | |
Qualitative Repeatability | ≤0.5% | |
Suppressor | Type | Self-Regeneration electrolytic micro-membrane suppressor |
Maximum Pressure | 6.0MPa | |
Non-Suppressed Chromatography | Yes/support | |
Void Volume | <40µL (4mm), <15µL (2mm) | |
Power Supply | 150W | |
External Size (L*W*H) | 350*470*495 (mm) | |
Net Weight (KG) | 26 | |
Gross Weight (KG) | 32 |