MSE PRO Ion Chromatography System Model 3
SKU: MA2608
MSE PRO™ Ion Chromatography System Model 3
Features
- Features a built-in eluent generator, eliminating the need for manual eluent preparation and enabling gradient elution.
- Utilizes a modular manufacturing process to ensure exceptional system stability.
- Equipped with integrated low-pressure degassing technology to remove bubble interference, enhancing stability.
- Compatible with a range of detectors, broadening the application possibilities of ion chromatography.
- Includes a bipolar conductivity detector for precise and versatile detection capabilities.
Technical Specifications
Ion Chromatographic Pump
- Pressure Range: 0~35 MPa
- Flow Range: 0.001~9.999 mL/min
- Pressure Display Accuracy: ≤0.1 MPa
- Flow Accuracy (Setting Error): RSD ≤0.1%
- Over-Pressure and Leak Protection: The system provides an alarm and stops operation in these conditions.
Digital Temperature-Control Detection System
1. Conductivity Detector
- Structure: Bipolar Conductivity Detector
- Detection Mode: Double conductivity detection
- Conductance Cell Size: ≤0.8 µL
- Output Voltage: -5000~5000 mV (adjustable)
- Measurement Range: 0~100000 µS/cm (10 selectable levels)
- Resolution: ≤0.0020 nS
- Conductance Cell Temperature: 5~60℃ (adjustable)
- Constant Temperature Accuracy: ±0.01℃
- Baseline Noise: ≤0.1% FS
- Baseline Drift: ≤0.3% FS
2. Flow System
- Pipeline Material: Entirely made of PEEK plastic materials
- Six-Way Valve: Rheodyne electromagnetic six-way valve (USA) with a compression resistance of 7000 psi, capable of automatic signal collection.
3. Built-In Low-Pressure Degassing Device
- Vacuum Degree: -70 kPa
- Inner Volume: 300 µL
- Organic Tolerance: 100%
- Maximum Flow Rate: 10 mL/min
- Degassing Efficiency: 90% at 1.0 mL/min
- Degassing Volume: 7.5 mL
4. Built-In Eluent Generator
- Eluent Types: KOH / NaOH
- Concentration Range: 0.1–100 mM/L
- Concentration Increment: 0.1 mM
- Flow Rate Range: 0.1–3.0 mL/min
- Maximum Operating Pressure: 20 MPa
- Minimum Operating Pressure: 5 MPa
5. Analytical Capabilities
- High-Capacity Anion Column: Supports pH 0~14, compatible with organic solvents, enabling simultaneous analysis with a single injection.
- High-Capacity Cation Column: Can separate and analyze substances like lysine and choline chloride.
- Transition and Heavy Metal Ion Detection: Multiple detector types support the analysis of various metallic and special ions.
6. Performance Metrics
- Qualitative Repeatability: ≤0.5% (Cl⁻, Na⁺)
- Quantitative Repeatability: ≤1.0% (Cl⁻, Na⁺)
- Linear Range: ≥10³
-
Minimum Detection Concentrations:
- Cl⁻: ≤0.0005 µg/mL
- BrO₃⁻: ≤0.001 µg/mL
- Li⁺: ≤0.001 µg/mL
7. Others
- Power Supply: 150W
- External Dimensions (L × W × H): 350 × 480 × 580 mm
- Net Weight: 34 kg
- Gross Weight: 40 kg