QuicKey Pro Human E-Cad(E-Cadherin) ELISA Kit

SKU: E-OSEL-H0017

  • $ 44295



QuicKey Pro Human E-Cad(E-Cadherin) ELISA Kit

Detection Range 15.63-1000 pg/mL
Sensitivity 9.38 pg/mL



Product Details

Properties

Assay type Sandwich-ELISA
Format 96T
Assay time 1.5h
Detection range 15.63-1000 pg/mL
Sensitivity 9.38 pg/mL
Sample type &Sample volume ; 50μL
Specificity This kit recognizes E-Cad in samples. No significant cross-reactivity or interference between E-Cad and analogues was observed.
Reproducibility Both intra-CV and inter-CV are < 10%.
Application This ELISA kit applies to the in vitro quantitative determination of E-Cad concentrations in .

 

Test Principle

This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human E-Cad. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Human E-Cad are added to the micro ELISA plate wells. Human E-Cad in samples (or standards) combines with the coated antibody and HRP linked detection antibody specific to E-Cad. Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450±2 nm. The concentration of Human E-Cad in the samples is then determined by comparing the OD of the samples to the standard curve.

 

Kit Components and Storage

An unopened kit can be stored at 2-8℃ for 6 months. After test, the unused wells and reagents should be stored according to the table.

Item Specifications Storage
Micro ELISA Plate(Dismountable) 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips
24T: 8 wells ×3 strips
96T*5: 5 plates, 96T
2-8℃, 1 months
Reference Standard 96T: 2 vials
48T/24T: 1 vial
96T*5: 10 vials
2-8℃, use the reconstituted standard within 24h
Concentrated HRP Linked Detection Ab(100×) 96T: 1 vial, 60 μL
48T/24T: 1 vial, 30 μL
96T*5: 5 vials, 60 μL
2-8℃(Protect from light)
Reference Standard & Sample Diluent 96T/48T/24T: 1 vial, 20 mL
96T*5: 5 vials, 20 mL
2-8℃
HRP Linked Ab Diluent 96T/48T/24T: 1 vial, 14 mL
96T*5: 5 vials, 14 mL
Concentrated Wash Buffer(25×) 96T/48T/24T: 1 vial, 30 mL
96T*5: 5 vials, 30 mL
Substrate Reagent 96T/48T/24T: 1 vial, 10 mL
96T*5: 5 vials, 10 mL
2-8℃(Protect from light)
Stop Solution 96T/48T/24T: 1 vial, 10 mL
96T*5: 5 vials, 10 mL
2-8℃
Plate Sealer 96T/48T/24T: 5 pieces
96T*5: 25 pieces
Product Description 1 copy
Certificate of Analysis 1 copy

 

Technical Data:

Precision


Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level E-Cad were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level E-Cad were tested on 3 different plates, 20 replicates in each plate.

  Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (pg/mL) 46.64 100.60 368.93 48.46 101.05 350.93
Standard deviation 3.26 5.68 19.96 2.67 5.10 11.48
CV (%) 7.00 5.65 5.41 5.52 5.05 3.27

 

 Recovery

The recovery of E-Cad spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 91-105 96
EDTA plasma(n=8) 91-102 96
Cell culture media(n=8) 90-105 97


Target Information

Database Links     SwissProt: P12830
Synonyms     CDH1, Arc-1, CD324, CDHE, LCAM, UVO, CAM 120/80, Epithelial Cadherin, Uvomorulin
Research Area     Cancer, Developmental biology, Signal transduction


Assay Procedures

1. Add 50µL standard or sample to the wells, Immediately add 50µL of HRP linked Detection Ab working solution to each well. Incubate for 60 min at 37°C.
2. Aspirate and wash the plate for 5 times.
3. Add 90µL of Substrate Reagent. Incubate for about 15 min at 37°C.
4. Add 50µL Stop Solution.
5. Read the plate at 450nm immediately. Calculation of the results