Radwag MA.X2.IC.A Moisture Analyzers with Internal Calibration
SKU: WL-306-0045
Radwag MA.X2.IC.A Moisture Analyzers with Internal Calibration
Radwag PUE 7.1.HRP High Resolution Scales
SKU # |
WL-306-0045 |
WL-306-0062 |
WL-306-0041 |
WL-306-0049 |
WL-306-0053 |
WL-306-0047 |
WL-306-0065 |
WL-306-0043 |
Model # |
MA 50/1.X2.IC.A |
MA 200/1.X2.IC.A |
MA 50.X2.IC.A |
MA 110.X2.IC.A |
MA 210.X2.IC.A |
MA 50/1.X2.IC.A.WH |
MA 200/1.X2.IC.A.WH |
MA 200/1.X2.IC.A.WH |
Maximum capacity(g) |
50 |
200 |
50 |
110 |
200 |
50 |
200 |
200 |
Readability(mg) |
0.1 |
0.1 |
1 |
1 |
1 |
1 |
0.1 |
1 |
SKU # |
WL-306-0051 |
WL-306-0055 |
WL-306-0076 |
WL-306-0079 |
WL-306-0074 |
WL-306-0081 |
WL-306-0083 |
Model # |
MA 110.X2.IC.A.WH |
MA 210.X2.IC.A.WH |
MA 50/1.X2.IC.A.NS |
MA 200/1.X2.IC.A.NS |
MA 50.X2.IC.A.NS |
MA 110.X2.IC.A.NS |
MA 210.X2.IC.A.NS |
Maximum capacity(g) |
110 |
200 |
50 |
200 |
50 |
110 |
210 |
Readability(mg) |
1 |
1 |
0.1 |
0.1 |
1 |
1 |
1 |
MA.X2.IC.A series
is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors.
Such solution allows:
- Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing.
- Remo
- ving any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity.
- Achieving high repeatability of opening and closing the drying chamber.
- Enhancing drying process automation.
- Enhancing safety of operation by eliminating contact with hot components of drying chamber.
- Improving operation ergonomics.
MA.X2.IC.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product.
Highlights of X2 Series moisture analyzers:
- Automatic opening and closing of the drying chamber
- 5” capacitive colour touchpad
- Modern interface
- Uncomplicated, intuitive operation
- Programmable display
- Drying profiles (standard, mild, step, fast)
- GLP/GMP printouts-reports
- Repeatable and customized applications
- Work optimization due to the use of halogen lamps
Capacity and temperature
MA.X2.IC.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional moisture analyzer with 250˚C maximum temperature).
An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather.
Databases:
Information system of X2 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis
Collected data is registered in 8 databases:
- Products (up to 5000 products)
- Users (up to 100 users)
- Packaging (up to 100 packagings)
- Customers (up to 1000 customers)
- Drying programs (up to 200 drying programs)
- Drying process reports (up to 5000 drying process reports)
- Ambient conditions (up to 10000 records)
- Weighings (up to 50000 records)
The results
The results obtained using the moisture analyzer (the final result of the drying process):
- % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
- % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
- % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
- g – the sample mass after drying.
Interfaces
USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer.Remote access to the moisture analyzer allows for online data management.
Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.
Datasheet
Model No. |
MA 50/1.X2.IC.A |
MA 200/1.X2.IC.A |
MA 50.X2.IC.A |
MA 110.X2.IC.A |
MA 210.X2.IC.A |
MA 50/1.X2.IC.A.WH |
MA 200/1.X2.IC.A.WH |
MA 50.X2.IC.A.WH |
Metrological parameters |
||||||||
Maximum capacity [Max] |
50 g |
200 |
50 |
110 |
210 |
50 |
200 |
50 |
Readability [d] |
0.1 mg |
0.1 mg |
0.1 mg |
1 mg |
1 mg |
0.1 mg |
0.1 mg |
1 mg |
Tare range |
-50 g |
-200 g |
-50 g |
-110 g |
-210 g |
-50 g |
-200 g |
-50 g |
Adjustment |
internal (automatic) |
|||||||
Maximum sample weight |
50 g |
200 g |
50 g |
110 g |
210 g |
50 g |
200 g |
50 g |
Heating module |
IR emitter |
halogen |
||||||
Moisture content repeatability |
+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g) |
|||||||
Moisture content readability |
0.0001% |
0.0001% |
0.0001% |
0.001% |
0.001% |
0.0001% |
0.0001% |
0.001% |
Drying temperature range |
Max 160°C |
Max 160°C |
Max 160°C |
Max 160°C |
Max 160°C |
Max 160 °C |
Max 160 °C |
Max 250 °C |
Physical parameters |
||||||||
Leveling system |
manual |
manual |
manual |
manual |
manual |
manual |
manual |
manual |
Display |
5” graphic color touchscreen |
|||||||
Weighing chamber |
automatic |
|||||||
Maximum sample height |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
Weighing pan dimensions |
ø90, h= 8 mm |
|||||||
Packaging dimensions |
476×381×346 mm |
|||||||
Net weight |
5.3 kg |
5.3 kg |
5.3 kg |
5.3 kg |
5.4 kg |
5.3 kg |
5.3 kg |
5.3 kg |
Gross weight |
7 kg |
7 kg |
7 kg |
6.8 kg |
6.9 kg |
7 kg |
7 kg |
6.8 kg |
Construction |
||||||||
Protection class |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
Features of use |
||||||||
Display mode |
%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC |
|||||||
Drying method |
4 drying profiles (standard, fast, step, mild) |
|||||||
Finish mode |
4 modes (automatic, manual, time-defined, user-defined) |
|||||||
Additional functions |
sample traceability |
|||||||
Communication interface |
||||||||
Communication interface |
RS232¹, USB-A, USB-B, Ethernet, Wi-Fi® |
|||||||
Electrical parameters |
||||||||
Power supply |
100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz |
|||||||
Power consumption |
6 W |
6 W |
6 W |
6 W |
6 W |
6 W |
6 W |
6 W |
Heating module power |
450 W |
450 W |
450 W |
450 W |
450 W |
450 W |
450 W |
450 W |
Environmental conditions |
||||||||
Operating temperature |
+10 — +40 °C |
|||||||
SOP – metrological tests |
||||||||
Mass indication control |
External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer) |
|||||||
Internal adjustment |
For .IC models only, GLP report |
|||||||
External adjustment |
For all models, GLP report |
|||||||
Drying temperature control |
One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer) |
|||||||
Moisture content indication control |
Certified MV Test Set |
|||||||
Adjustment |
||||||||
Internal / External adjustment |
Depending on the type of moisture analyzer, GLP report |
|||||||
Drying temperature adjustment |
Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer) |
Model No. |
MA 110.X2.IC.A.WH |
MA 210.X2.IC.A.NS |
MA 50/1.X2.IC.A.NS |
MA 200/1.X2.IC.A.NS |
MA 50.X2.IC.A.NS |
MA 110.X2.IC.A.NS |
MA 210.X2.IC.A.NS |
Metrological parameters |
|||||||
Maximum capacity [Max] |
110 g |
210 g |
50 g |
200 g |
50 g |
110 g |
210 g |
Readability [d] |
1 mg |
1 mg |
0.1 mg |
0.1 mg |
1 mg |
1 mg |
1 mg |
Tare range |
-50 g |
-210 g |
-50 g |
-200 g |
-50 g |
-110 g |
-210 g |
Adjustment |
internal (automatic) |
||||||
Maximum sample weight |
110 g |
210 g |
50 g |
200 g |
50 g |
110 g |
210 g |
Heating module |
halogen |
metal heater |
|||||
Moisture content repeatability |
+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g) |
||||||
Moisture content readability |
0.001% |
0.001% |
0.0001% |
0.0001% |
0.001% |
0.001% |
0.001% |
Drying temperature range |
Max 250 °C |
Max 250 °C |
Max 160 °C |
Max 160 °C |
Max 160 °C |
Max 160 °C |
Max 160 °C |
Physical parameters |
|||||||
Leveling system |
manual |
||||||
Display |
5” graphic color touchscreen |
||||||
Weighing chamber |
automatic |
||||||
Maximum sample height |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
Weighing pan dimensions |
ø90, h= 8 mm |
||||||
Packaging dimensions |
476×381×346 mm |
||||||
Net weight |
5.3 kg |
5.3 kg |
5.4 kg |
5.3 kg |
5.3 kg |
5.3 kg |
5.4 kg |
Gross weight |
6.8 kg |
6.9 kg |
6.8 kg |
6.8 kg |
6.8 kg |
6.8 kg |
6.9 kg |
Construction |
|||||||
Protection class |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
Features of use |
|||||||
Display mode |
%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC |
||||||
Drying method |
4 drying profiles (standard, fast, step, mild) |
||||||
Finish mode |
4 modes (automatic, manual, time-defined, user-defined) |
||||||
Additional functions |
sample traceability |
||||||
Communication interface |
|||||||
Communication interface |
RS232¹, USB-A, USB-B, Ethernet, Wi-Fi® |
||||||
Electrical parameters |
|||||||
Power supply |
100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz |
||||||
Power consumption |
6 W |
6 W |
6 W |
6 W |
6 W |
6 W |
6 W |
Heating module power |
450 W |
450 W |
450 W |
450 W |
450 W |
450 W |
450 W |
Environmental conditions |
|||||||
Operating temperature |
+10 — +40 °C |
||||||
SOP – metrological tests |
|||||||
Mass indication control |
External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer) |
||||||
Internal adjustment |
For .IC models only, GLP report |
||||||
External adjustment |
For all models, GLP report |
||||||
Drying temperature control |
One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer) |
||||||
Moisture content indication control |
Certified MV Test Set |
||||||
Adjustment |
|||||||
Internal / External adjustment |
Depending on the type of moisture analyzer, GLP report |
||||||
Drying temperature adjustment |
Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer) |
*The power supply can be connected to the socket on the back of the balance housing or to the terminal.
MSE Supplies is an authorized distributor for RADWAG.