Spectro-Electrochemical Cell with Adjustable Optical Length (0.3 to 4 mm)

SKU: B-A-MM_SPEC_EFC_4mm-.7-new

  • $ 10,37995



Spectro-Electrochemical Cell with Adjustable Optical Length (0.3 to 4 mm)

Buy Redox.me products from MSE Supplies at the best value.

Custom Product: 10 x 10 mm2 WE, aqueous electrolyte, including Pt CE and Ag/AgCl 

This is a horizontally mounted, multi-purpose spectroelectrochemical cell with 4 mm long optical path (i.e. electrolyte thickness) designed to be used with standard UV-Vis or IR spectrometers. It enables obtaining electrochemical and spectroscopic information from liquid sample or thin film in systems where variations in applied potential induce changes in observed spectra. It consists of a polyether ether ketone (PEEK) flow chamber equipped with magnetic mount sample holder (a screw version is available on request), screw mount quartz window holder and two different mini tripods. It well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements. Unlike Spectro-EFC 1.75 mL, this cell is meant to be used with pseudo-reference electrode (50 mm long) and counter electrode in the form of a metal wire (90 mm long), both with plug of 6 mm in diameter. Thanks to the application of pseudo-reference electrode, the thickness of an electrolyte is reduced from 12 mm down to 4 mm.

Application note:

Spectroelectrochemical cell is used to study the relation between absorbance/transmittance and electrochemical potential. It enables real-time monitoring of optical change in electrochromic materials. It also enables in-situ spectral acquisition for detection, identification and characterization of short-lived electrochemically-generated species/intermediates, resulting in a detailed investigation of the mechanistic pathways of redox processes.

Specification:

Nominal exposure area: 1 cm2 (other values on request)
Optical path length (electrolyte thickness): 4 mm
Flow chamber volume: 0.7 mL
Maximum substrate thickness: 4 mm
Electrode plug diameter: 6 mm
Minimum substrate size: 17 mm x 25 mm
Recommended substrate size: 25 mm x 25 mm

Product Includes

1 x sample mount – 0049CPEMAMM
1 x flow chamber – 0050CPEMAMM
1 x quartz window - 0045PQGMA
1 x window holder - 0051PSSMA
1 x set of screws – 0032PNYCM
1 x plug
1 x Manfrotto PIXI table tripod – 0028PHYCM
1 x XS Bendy Flexible Tripod - 0043PHYCM

Setup Includes:

mm Spectro-Efc, 4 Mm Path, 0.7 ml - Magnetic Mount Spectro-Electrochemical Flow Cell With Reduced Optical Path, 4 mm Path, 0.7 ml
Pseudo-Reference Electrode - Pr 0.6/50 mm, Platinum (99,9%)
 Metal Wire Auxiliary Electrode - St 0.6/90 mm, Platinum (99,9%)