Vitamin E (VE) Colorimetric Assay Kit
SKU: E-BC-K033-M-96
To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.
Vitamin E (VE) Colorimetric Assay Kit
SKU # | E-BC-K033-M |
Detection Instrument | Microplate reader (525-533 nm, optimum wavelength: 533 nm) |
Detection Method | Colorimetric method |
Product Details
Properties
Synonyms | VE |
Sample Type | Serum, plasma, tissue |
Sensitivity | 0.95 μg/mL |
Detection Range | 0.95-40 μg/mL |
Detection Method | Colorimetric method |
Assay type | Quantitative |
Assay time | 30 min |
Precision | Average inter-assay CV: 6.300% | Average intra-assay CV: 3.900% |
Other instruments required | Micropipettor, Centrifuge, Vortex mixer |
Other reagents required | Normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4), Absolute ethanol, N-heptane |
Storage | 2-8℃ |
Valid period | 12 months |
Dilution of Sample
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.95-40 μg/mL).
The recommended dilution factor for different samples is as follows (for reference only)
Sample type | Dilution factor |
Human serum | 1 |
Mouse serum | 1 |
Chicken serum | 1 |
10% Mouse liver tissue homogenate | 1 |
10% Mouse brain tissue homogenate | 1 |
10% Rat kidney tissue homogenate | 1 |
10% Rat lung tissue homogenate | 1 |
10% Rat spleen tissue homogenate | 1 |
10% Rat heart tissue homogenate | 1 |
Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).
Detection Principle
Fe3+ can be deoxidized to Fe2+ by VE with ferroin existing. Fe2+ can react with phenanthroline and form pink compound under certain condition. After colorimetric assay, VE content can be figured out according to the standard curve or calculated through formula.
Kit Components & Storage
Item | Component | Size 1(48 T) | Size 2(96 T) | Storage |
Reagent 1 | Chromogenic Agent | Powder × 1 vial | Powder × 1 vial | 2-8℃, 12 months shading light |
Reagent 2 | Ferrum Reagent | Powder × 1 vial | Powder × 1 vial | 2-8℃, 12 months shading light |
Reagent 3 | Stop Solution | 1.5 mL × 1 vial | 1.5 mL × 2 vials | 2-8℃, 12 months |
Reagent 4 | Homogenized Medium | 50 mL × 1 vial | 50 mL × 2 vials | 2-8℃, 12 months |
Reagent 5 | 1 mg/mL VE Standard | 0.4 mL × 1 vial | 0.4 mL × 1 vial | 2-8℃, 12 months shading light |
Microplate | 96 wells | No requirement | ||
Plate Sealer | 2 pieces |
Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.
Technical Data:
Parameter:
Intra-assay Precision
Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).
Parameters | Sample 1 | Sample 2 | Sample 3 |
Mean (μg/mL) | 2.60 | 24.50 | 32.50 |
%CV | 4.3 | 3.7 | 3.7 |
Inter-assay Precision
Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.
Parameters | Sample 1 | Sample 2 | Sample 3 |
Mean (μg/mL) | 2.60 | 24.50 | 32.50 |
%CV | 6.1 | 6.4 | 6.4 |
Recovery
Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 97%.
Standard 1 | Standard 2 | Standard 3 | |
Expected Conc. (μg/mL) | 7.5 | 18 | 27.5 |
Observed Conc. (μg/mL) | 7.1 | 17.8 | 26.7 |
Recovery rate (%) | 95 | 99 | 97 |
Sensitivity
The analytical sensitivity of the assay is 0.95 μg/mL VE. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.
Standard Curve:
As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:
Concentration (μg/mL) | 0 | 5 | 10 | 15 | 20 | 25 | 30 | 40 |
Average OD | 0.072 | 0.142 | 0.190 | 0.247 | 0.309 | 0.362 | 0.438 | 0.541 |
Absoluted OD | 0 | 0.070 | 0.118 | 0.175 | 0.237 | 0.290 | 0.366 | 0.469 |