Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Zinc (Zn) Colorimetric Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Zinc (Zn) Colorimetric Assay Kit

SKU: E-BC-K137-M-500

  • $ 42595



Zinc (Zn) Colorimetric Assay Kit

SKU # E-BC-K137-M
Detection Instrument Microplate reader (545-575 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms Zn
Sample Type Serum, plasma, urine, milk
Sensitivity 0.418 μmol/L
Detection Range 0.748 -46.2 μmol/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 20 min
Precision Average inter-assay CV: 4% | Average intra-assay CV: 2.700%
Other instruments required Micropipettor, Vortex mixer
Other reagents required Deionized water
Storage 2-8℃
Valid period 12 months

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.748 -46.2 μmol/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human urine 1
Human serum 1
Human milk 1
Rat serum 1

 

Note: The diluent is deionized water.

 

Detection Principle

The zinc ion in the sample react with 5-Br-PADAP to produce the colored complex. The depth of color is directly proportional to the concentration of zinc ion. Zinc ion content can be calculated by measuring the OD values at 560 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 1.54 mmol/L Zinc Standard 0.5 mL × 1 vial 0.5 mL × 1 vial 2-8°C, 12 months
Reagent 2 Protein Precipitator 15 mL ×1 vial 15 mL ×1 vial 2-8°C, 12 months
Reagent 3 Chromogenic Agent 0.13 mL × 1 vial 0.26 mL × 1 vial 2-8°C, 12 months, shading light
Reagent 4 Buffer Solution 13 mL × 1 vial 26 mL × 1 vial 2-8°C, 12 months, shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (μmol/L) 2.50 22.50 30.50
%CV 2.9 2.5 2.7


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (μmol/L) 2.50 22.50 30.50
%CV 4.3 4.2 3.5

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 104%.

Standard 1 Standard 2 Standard 3
Expected Conc. (μmol/L) 6.12 14.05 25.7
Observed Conc. (μmol/L) 6.4 14.3 27.0
Recovery rate (%) 105 102 105

 

Sensitivity

The analytical sensitivity of the assay is 0.418 μmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (μmol/L) 0 3.85 7.7 11.55 15.4 23.1 30.08 46.2
Average OD 0.116 0.169 0.234 0.291 0.348 0.475 0.591 0.819
Absoluted OD 0 0.053 0.118 0.175 0.232 0.359 0.475 0.703