Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

5’-Nucleotidase (5'-NT) Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

5’-Nucleotidase (5'-NT) Activity Assay Kit

SKU: E-BC-K196-M-500

  • $ 85095
  • Save $ 15000


5’-Nucleotidase (5'-NT) Activity Assay Kit

SKU # E-BC-K196-M
Detection Instrument Microplate reader (550 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms 5’-NT
Sample Type Serum, plasma, animal tissue
Sensitivity 28.0 U/L
Detection Range 28.0-581 U/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 30 min
Precision Average inter-assay CV: 6% | Average intra-assay CV: 3.300%
Other instruments required Pipettor, Water bath, Centrifuge
Other reagents required Normal saline (0.9% NaCl)
Storage 2-8℃
Valid period 12 months


Detection Principle

5'-Nucleotide enzyme (5'-NT, EC 3.1.3.5), full name is 5'-ribonucleotide phosphohydrolase, is a special phosphohydrolase that specifically hydrolyzes 5'-phosphoric acid attached to pentose in 5'-nucleotide. This enzyme is widely distributed in the cell membrane of various tissues of human and animal. Only the 5'-NT released by the tissue cells of the hepatobiliary system may enter the blood. Therefore, the source of serum 5'-NT has certain specificity, and the determination of serum 5'-NT has important value for the diagnosis of hepatobiliary diseases.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Working Solution 10 mL × 1 vial 20 mL × 1 vial 2-8°C, 12 months, shading light
Reagent 2 Chromogenic Agent 5 mL × 1 vial 10 mL × 1 vial 2-8°C, 12 months, shading light
Reagent 3 0.6 mmol/L Inosine Standard Solution 2 mL × 1 vial 2 mL × 1 vial 2-8°C, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 52.00 227.00 406.00
%CV 3.8 3.4 2.7


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators
to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 52.00 227.00 406.00
%CV 6.1 6.3 5.6

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 105%.

Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.21 0.34 0.45
Observed Conc. (mmol/L) 0.2 0.4 0.5
Recovery rate (%) 108 103 104

 

Sensitivity

The analytical sensitivity of the assay is 28.0 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only.

Concentration (mmol/L) 0.00 0.12 0.24 0.3 0.36 0.42 0.48 0.60
OD value 0.046 0.073 0.100 0.116 0.126 0.143 0.153 0.192
0.045 0.072 0.087 0.115 0.126 0.147 0.158 0.184
Average OD 0.046 0.073 0.093 0.115 0.126 0.145 0.155 0.188
Absoluted OD 0.000 0.027 0.048 0.069 0.080 0.099 0.110 0.142