Ca2+-ATPase Activity Assay Kit

SKU: E-BC-K212-M-96

  • $ 22195
  • Save $ 3900



Ca2+-ATPase Activity Assay Kit

SKU # E-BC-K212-M
Detection Instrument Microplate reader (660 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms Ca2+-ATPase
Sample Type Animal tissue
Sensitivity 1.18 U/kg wet weight
Detection Range 1.18-286.43 U/kg wet weight
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 90 min
Precision Average inter-assay CV: 8% | Average intra-assay CV: 6%
Other instruments required Test tube, Vortex mixer, Incubator, Centrifuge, 100°C water bath, Microplate reader
Other reagents required Ultrapure water, Normal saline (0.9% NaCl)
Storage 2-8℃
Valid period 12 months


Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Rat liver tissue homogenate 5-8
10% Mouse liver tissue homogenate 1
10% Rat heart tissue homogenate 5-8
10% Rat lung tissue homogenate 5-8
10% Rat kidney tissue homogenate 5-8
10% Rat brain tissue homogenate 2-3

 

Note: The diluent is normal saline (0.9% NaCl). For the dilution of other sample types, please do pretest to confirm the dilution factor.


Detection Principle

ATPase can decompose ATP to produce inorganic phosphorus. The activity of ATPase can be expressed by measuring the production amount of inorganic phosphorus in unit time. In the control system, Ca2+ -ATPase activity was inhibited, while in the sample system, Ca2+ -ATPase activity was not inhibited. The difference of inorganic phosphorus content between the sample and the control was the inorganic phosphorus produced by Ca2+ -ATPase during the incubation time. The activity of Ca2+ -ATPase was determined by inorganic phosphorus production.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Buffer Solution 10 mL x 1 vial 20 mL x 1 vial 2-8°C, 12 months
Reagent 2 Activator A 1 mL x 1 vial 2 mL x 1 vial 2-8°C, 12 months
Reagent 3 Activator B 1 mL x 1 vial 2 mL x 1 vial 2-8°C, 12 months
Reagent 4 Substrate Powder x 1 vial Powder x 1 vial 2-8°C, 12 months
Reagent 5 Protein Precipitator 3 mL x 1 vial 6 mL x 1 vial 2-8°C, 12 months
Reagent 6 Chromogenic Agent A Powder x 1 vial Powder x 2 vials 2-8°C, 12 months shading light
Reagent 7 Acid Reagent 5 mL x 1 vial 10 mL x 1 vial 2-8°C, 12 months
Reagent 8 Chromogenic Agent B Powder x 1 vial Powder x 2 vials 2-8°C, 12 months
Reagent 9 10 mmol/L Standard Solution 2 mL x 1 vial 2 mL x 1 vial 2-8°C, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three rat liver samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (U/kg wet weight) 5.60 85.40 195.00
%CV 6.5 6.1 5.4


Inter-assay Precision

Three rat liver samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/kg wet weight) 5.60 85.40 195.00
%CV 7.6 8.2 8.2

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 107%.

Sample 1 Sample 2 Sample 3
Expected Conc. (U/kg wet weight) 25.8 103 242
Observed Conc. (U/kg wet weight) 28.4 111.2 249.3
Recovery rate (%) 110 108 103

 

Sensitivity

The analytical sensitivity of the assay is 1.18 U/kg wet weight. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.