Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Diamine Oxidase (DAO) Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Diamine Oxidase (DAO) Activity Assay Kit

SKU: E-BC-K524-M-96

  • $ 27295
  • Save $ 4800



Diamine Oxidase (DAO) Activity Assay Kit

SKU # E-BC-K524-M
Detection Instrument Microplate reader (450-470 nm, optimum wavelength: 460 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms DAO
Sample type Serum, plasma, urine, animal tissue and cell samples
Sensitivity 7.39 U/L
Detection range 7.39-134.15 U/L
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 60 min
Precision Average inter-assay CV: 7% | Average intra-assay CV: 5%
Other instruments required Centrifuge, Incubator, Microplate reader
Storage 2-8℃
Valid period 12 months


Images

L Zhao et al investigate the osteoporosis and altered gut microbiota induced by ethanol. Diamine oxidase (DAO) activity of rat serum was determined using DAO activity assay kit (E-BC-K524-M).

Activity of DAO was significantly induced by ethanol. (**P<0.01)

 

Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human serum 2-4
Human plasma 1
Rat serum 1
Rat plasma 1
Mouse serum 1
Mouse plasma 1
10% Rat liver tissue homogenate 1
10% Rat kidney tissue homogenate 1
10% Rat heart tissue homogenate 1
Human urine 1
Hela Cells (1×106) 1

 

Note: The diluent is buffer solution. For the dilution of other sample types, please do pretest to confirm the dilution factor

 

Detection Principle

Diamine oxidase can catalyse amine substances to produce hydrogen peroxide, and hydrogen peroxide can react with the chromogenic substance to produce chromogenic substance, which has a characteristic absorption peak at 460 nm. The activity of diamine oxidase can be calculated by measuring the change rate of absorbance per unit time.

 

Kit Components & Storage

Item Component Size (96 T) Storage
Reagent 1 Buffer Solution 60 mL × 1 vial 2-8℃, 12 months
Reagent 2 Substrate 1.5 mL × 2 vials 2-8℃, 12 months
shading light
Reagent 3 Enzyme Reagent Powder × 1 vial 2-8℃, 12 months
shading light
Reagent 4 Chromogenic Agent Powder × 1 vial 2-8℃, 12 months
shading light
Reagent 5 Stop Agent 10 mL × 1 vial 2-8℃, 12 months
Reagent 6 100 mmol/L Standard 1 mL × 1 vial 2-8℃, 12 months
shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 18.4 62.5 112.0
%CV 5.6 5.2 4.2


Inter-assay Precision

Three human serum samples were assayed 17 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 18.4 62.5 112.0
%CV 6.4 7.2 7.4


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 105%.


Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.35 0.94 1.3
Observed Conc. (mmol/L) 0.4 1.0 1.4
Recovery rate (%) 101 106 108

 

Sensitivity

The analytical sensitivity of the assay is 7.39 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mmol/L) 0 0.2 0.5 0.7 1.0 1.2 1.5 2.0
OD value 0.065 0.098 0.161 0.198 0.280 0.336 0.413 0.556
0.064 0.100 0.160 0.208 0.282 0.336 0.419 0.555
Average OD 0.065 0.099 0.161 0.203 0.281 0.336 0.416 0.556
Absoluted OD 0.000 0.035 0.096 0.139 0.217 0.272 0.352 0.491