Glutamate Dehydrogenase (GDH) Activity Assay Kit

SKU # E-BC-K759-M
Detection Instrument Microplate reader (440-460 nm, optimum wavelength: 450 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms GDH
Sample type Serum (plasma), urine, animal tissue
Sensitivity 0.54 U /L
Detection range 0.54-25.0 U/L
Detection method Colorimetric method
Assay type Enzyme Activity
Assay time 35 min
Precision Average inter-assay CV: 4% | Average intra-assay CV: 3%
Other instruments required Incubator(37℃), centrifuge
Other reagents required Double distilled water
Storage 2-8℃
Valid period 12 months


Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (20-2000 U/mL).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Rat liver tissue homogenate 3-5
10% Rat kidney tissue homogenate 1
10% Rat heart tissue homogenate 1
10% Rat brain tissue homogenate 1
10% Rat spleen tissue homogenate 1
10% Rat lung tissue homogenate 1
10% Mouse liver tissue homogenate 1
10% Mouse kidney tissue homogenate 1
10% Mouse spleen tissue homogenate 1
10% Mouse lung tissue homogenate 1
Human serum 1
Human plasma 1
Rat serum 1
Rat plasma 1

 

Note: The diluent is extracting solution. For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Detection Principle

GDH catalyzes the dehydrogenation of glutamate, meanwhile, NAD+ is reduced to NADH, Which under the action of hydrogen transmitter, transfer electrons to WST-8 to produce the yellow product. The activity of GDH can be calculated by measuring the change of absorbance value at 450 nm.

 

Kit Components & Storage

Item Component Size (96 T) Storage
Reagent 1 Extracting Solution 50 mL × 1 vial 2-8℃, 12 months
Reagent 2 Buffer Solution 15 mL × 1 vial 2-8℃, 12 months
Reagent 3 Substrate A Powder × 1 vial 2-8℃, 12 months, shading light
Reagent 4 Substrate B 5 mL × 1 vial 2-8℃, 12 months
Reagent 5 Chromogenic Agent 1.2 mL × 2 vials 2-8℃, 12 months, shading light
Reagent 6 Standard Powder × 2 vials 2-8℃, 12 months, shading light

Microplate 96 wells No requirement

Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 1.50 9.80 13.50
%CV 3.5 3.2 2.3


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 1.50 9.80 13.50
%CV 3.7 4.1 4.2

  

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 98%.

Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.07 0.23 0.35
Observed Conc. (mmol/L) 0.1 0.2 0.4
Recovery rate (%) 101 104 104

 

Sensitivity

The analytical sensitivity of the assay is 0.54 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mmol/L) 0 0.05 0.10 0.20 0.25 0.30 0.40 0.50
Average OD 0.049 0.115 0.201 0.363 0.439 0.531 0.696 0.889
Absoluted OD 0.000 0.066 0.152 0.314 0.390 0.482 0.647 0.840