Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

γ-Glutamyl Transferase (GGT/γ-GT) Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

γ-Glutamyl Transferase (GGT/γ-GT) Activity Assay Kit

SKU: E-BC-K126-M-96

To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.

γ-Glutamyl Transferase (GGT/γ-GT) Activity Assay Kit

SKU # E-BC-K126-M
Detection Instrument Microplate reader (405 nm)
Detection Method Colorimetric method


Product Details

Properties

Synonyms GGT/γ-GT
Sample Type Serum, plasma, animal tissue
Sensitivity 0.88 U/L
Detection Range 0.88-399.4 U/L
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 20 min
Precision Average inter-assay CV: 6.200% | Average intra-assay CV: 4.200%
Other instruments required Micropipettor, Vortex mixer, Centrifuge, Water bath, Incubator
Storage 2-8℃
Valid period 12 months

 

Images

GX Xu et al investigate the effect of endothelin receptor B in enhancing liver injury and pro-inflammatory. Activity of γ-glutamyl transferase of human serum was determined using γ-GT activity assay kit (E-BC-K126-M).

The activity of γ-GT was significantly increased in PBC patients. (**P<0.05)

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.88-399.4 U/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Mouse serum 1
Human serum 1
Rat serum 1
Dog serum 1
Human plasma 1
Horse serum 1
Porcine serum 1
 Human hydrothorax 1
10% Mouse liver tissue homogenate 1
10% Mouse heart tissue homogenate 1
10% Rat spleen tissue homogenate 1
10% Rat lung tissue homogenate 1

 

Note: The diluent is reagent 3.

 

Detection Principle

γ-GT catalyzes the transfer of gamma glutamyl group from glutamyl p-nitroaniline to N-glycyl glycine to produce p-nitroaniline, which has characteristic absorption peak at 405nm. The activity of γ-GT can be calculated according to the changing rate of absorbance value.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Buffer Solution 15 mL ×1 vial 30 mL ×1 vial 2-8°C, 12 months
Reagent 2 Substrate Powder ×1 vial Powder ×2 vials 2-8°C, 12 months, shading light
Reagent 3 Extracting
Solution
50 mL ×1 vial  50 mL ×2 vials 2-8°C, 12 months
Reagent 4 1.0 mmol/L p-Nitroaniline Standard Solution 1.5 mL ×1 vial 1.5 mL ×1 vial 2-8°C, 12 months
Reagent 5 Standard Diluent 10 mL ×1 vial 10 mL ×1 vial 2-8°C, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 2.50 94.60 207.00
%CV 4.5 4.0 4.1


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 2.50 94.60 207.00
%CV 6.0 6.3 6.3

 

Sensitivity

The analytical sensitivity of the assay is 0.88 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve:

As the OD value of the standard curve may vary according to the conditions of the
actual assay performance (e.g. operator, pipetting technique or temperature effects),
so the standard curve and data are provided as below for reference only:

Concentration (μmol/L) 0 200 400 500 600 800 900 1000
OD value 0.042 0.364 0.656 0.844 1.051 1.355 1.485 1.678
0.042 0.367 0.710 0.862 1.027 1.351 1.474 1.606
Average OD 0.042 0.366 0.683 0.853 1.039 1.353 1.480 1.642
Absoluted OD 0.000 0.324 0.641 0.811 0.997 1.311 1.438 1.600