IKA C 1 Package 2/12 Calorimeters
SKU: 0010002416
IKA C 1 Package 2/12 Calorimeters
Buy IKA products from MSE Supplies at the best value.
MSE Supplies is an authorized distributor of IKA.
Product Details
Item number: 0010002416
The C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler. The light and simply attachable combustion chamber allows an easy measurement preparation. Due to the variety of different interfaces (PC, balance, printer) this unit is easily adaptable depending on the customer’s specific application needs. Further adaption to data management and LIMS is possible with our calorimeter software C 6040 Calwin (accessory).
The C 1 calorimeter can only be operated together with a fitted cooling water supply unit. Therefore we recommend our C 1 Package 1/12 for best performance. It includes the chiller RC 2 basic and ensures best possible connectivity and function of the calorimeter.
The scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The catalytic activated, halogen resistant combustion chamber C 1.12 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). It is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible.
Scope of delivery
- C 1 S000
- C 1.12 Combustion chamber, halogen resistant
About IKA
Founded in 1910 as a supplier for pharmacies and hospitals, the company left bombed-out Cologne for Staufen im Breisgau in 1942. There it quickly became the world's leading company for laboratory technology as well as dispersing, stirring and kneading machines.
Technical Data of IKA C 1 Package 2/12 Calorimeters
Measuring range max. | 40000 J |
Measuring mode static jacket 22°C | yes |
Measuring mode static jacket 30°C | yes |
Measurements/h static jacket | 4 |
Reproducibility static jacke (1g benzoic acid NBS39i) | 0.15 %RSD |
Working temperature | 20 - 30 °C |
Temperature measurement resolution | 0.0001 K |
Cooling medium temperature | 18 - 29 °C |
Cooling medium permissible operating pressure | 1.5 bar |
Cooling medium | tap water |
Type of cooling | flow |
Flow rate | 50 - 60 l/h |
Rec. flow rate at 18°C | 55 l/h |
Oxygen operating pressure max. | 40 bar |
Interface scale | RS232 |
Interface printer | RS232 |
Interface PC | RS232 |
Oxygen filling | yes |
Degasification | yes |
Decomposition vessel integrated | yes |
Decomposition vessel, halogen resistant | yes |
Analysis according to DIN 51900 | yes |
Analysis according to ISO 1928 | yes |
Dimensions (W x H x D) | 290 x 280 x 300 mm |
Weight | 22.59 kg |
Permissible ambient temperature | 5 - 40 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 20 |
RS 232 interface | yes |
USB interface | yes |
Voltage | 100 - 240 V |
Frequency | 50/60 Hz |
Power input | 120 W |