Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Mitochondrial Complex IV (Cytochrome C Oxidase) Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Mitochondrial Complex IV (Cytochrome C Oxidase ) Activity Assay Kit

SKU: E-BC-K152-M-96

  • $ 40895
  • Save $ 7200



Mitochondrial Complex IV (Cytochrome C Oxidase ) Activity Assay Kit

SKU # E-BC-K152-M
Detection Instrument Microplate reader (540-560 nm, optimum wavelength: 550 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms Animal tissue
Sensitivity 3.0 U/L
Detection Range 3.0–88.6 U/L
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 10 min
Precision Average inter-assay CV: 9.500% | Average intra-assay CV: 5%
Other instruments required Centrifuge
Other reagents required Anhydrous ethanol, PBS(0.01 M,pH 7.4)
Storage -20℃
Valid period 12 months


Detection Principle

Mitochondrial complex IV can catalyze the oxidation of reduced cytochrome C to oxidized cytochrome C, which has an absorption wavelength at 550 nm. Therefore, the activity of mitochondrial complex IV can be quantified by measure the change OD value at 550 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Extracting
Solution A
50 mL ×1 vial 50 mL × 2 vials -20°C, 12 months
Reagent 2 Extracting
Solution B
25 mL × 1 vial 50 mL × 1 vial -20°C, 12 months
Reagent 3 Inhibitor Powder ×1 vial Powder × 2 vials -20°C, 12 months,
shading light
Reagent 4 Substrate Powder ×1 vial Powder × 2 vials -20°C, 12 months,
shading light
Reagent 5 Stabilizer Powder ×1 vial Powder × 2 vials -20°C, 12 months,
shading light
Reagent 6 Buffer Solution 13 mL×1 vial 26 mL×1 vial 20°C, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three rat brain tissue samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (μmol/L) 8.50 34.60 70.50
%CV 5.1 5.0 4.9


Inter-assay Precision

Three rat brain tissue samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (μmol/L) 8.50 34.60 70.50
%CV 9.8 9.1 9.6

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 104%.

Sample 1 Sample 2 Sample 3
Expected Conc. (μmol/L) 18.5 42.7 65.1
Observed Conc. (μmol/L) 18.7 44.8 69.0
Recovery rate (%) 101 105 106

 

Sensitivity

The analytical sensitivity of the assay is 3.0 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.