Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

QuicKey Human IgG(Immunoglobulin G) ELISA Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

QuicKey Human IgG(Immunoglobulin G) ELISA Kit

SKU: E-TSEL-H0011

  • $ 33195
  • Save $ 5900


QuicKey Human IgG(Immunoglobulin G) ELISA Kit

Detection Range 1.56-100 ng/mL
Sensitivity 0.64 ng/mL



Product Details

Properties

Assay type Sandwich-ELISA
Format 96T
Assay time 2.5h
Detection range 1.56-100 ng/mL
Sensitivity 0.64 ng/mL
Sample type &Sample volume serum, plasma, urine, saliva; 50μL
Specificity This kit recognizes Human IgG in samples. No significant or interference between Human IgG and analogues was observed.
Reproducibility Both intra-CV and inter-CV are < 10%.
Application This ELISA kit applies to the in vitro quantitative determination of Human IgG concentrations in serum, plasma, urine, saliva.Please consult technical support for the applicability if other biological fluids need to be tested.

 

Test Principle

This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human IgG. Samples (or Standards) and biotinylated detection antibody specific for Human IgG are added to the micro ELISA plate wells. Human IgG would combine with the specific antibody. Then Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IgG, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 ± 2 nm. The OD value is proportional to the concentration of Human IgG. You can calculate the concentration of Human IgG in the samples by comparing the OD of the samples to the standard curve.

 

Kit Components and Storage

An unopened kit can be stored at 2-8℃ for six months. After test, the unused wells and reagents should be stored according to the table below.

Item Specifications Storage conditions after test
Micro ELISA Plate (Dismountable) 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips
2-8℃, 1 month
Reference Standard 96T: 2 vials
48T: 1 vial
Discard unused reconstituted standard and dilutions
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8℃
Biotinylated Detection Ab Working Solution 1 vial, 6 mL
HRP Conjugate Diluent 1 vial, 14 mL
Concentrated Wash Buffer (25×) 1 vial, 30 mL
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL
2-8℃ (Protect from light)
Substrate Reagent 1 vial, 10 mL
Stop Solution 1 vial, 10 mL 2-8℃
Plate Sealer 5 pieces
Product Description 1 copy
Certificate of Analysis 1 copy

 

Technical Data:

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human IgG were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human IgG were tested on 3 different plates, 20 replicates in each plate.

  Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean (ng/mL) 4.91 11.20 44.60 4.94 11.66 47.68
Standard deviation 0.26 0.51 1.95 0.25 0.56 2.24
CV (%) 5.30 4.55 4.37 5.06 4.80 4.70

 

 Recovery

The recovery of Human IgG spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 87-98 93
EDTA plasma(n=8) 91-100 95
Urine(n=8) 83-107 94


Target Information

Background

Immunoglobulin G (IgG) is a class of immunoglobulins found in all body fluids. They are the smallest but most common antibodies (75 percent to 80 percent) in the body. IgG antibodies are large molecules of about 150 kDa[1], made of four peptide chains. It contains two identical class γ heavy chains of about 50 kDa and two identical light chains of about 25 kDa, thus a tetrameric quaternary structure. IgG antibodies are very important in fighting bacterial and viral infections, and they are the only type of antibody that can cross the placenta in a pregnant woman to help the fetus. The measurement of immunoglobulin G can be a diagnostic tool for certain conditions, such as autoimmune hepatitis, if indicated by certain symptoms. Clinically, measured IgG antibody levels are generally considered to be indicative of an individual's immune status to particular pathogens. A common example of this practice are titers drawn to demonstrate serologic immunity to measles, mumps, and rubella (MMR), hepatitis B virus, and varicella (chickenpox) [2].
1. Jr C A J, Travers P, Walport M, et al. Principles of innate and adaptive immunity [J]. 2001.
2. Faruque A A, Maoya J, et al. Analysis of surface plasmon resonance biosensors for protein detection. 2016.

Research Area Immunology


Assay Procedures

step01

1. Add 50μL standard or sample to the wells, immediately add 50μL Biotinylated Detection Ab working solution to each well. Incubate for 90 min at 37°C

step02

2. Aspirate and wash the plate for 3 times

step03

3. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times

step04

4. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C

step05

5. Add 50μL Stop Solution

step06

6. Read the plate at 450nm immediately. Calculation of the results