SKU: WL-306-0045

  • $ 2,40995
  • Save $ 42500


Radwag MA.X2.IC.A Moisture Analyzers with Internal Calibration

Radwag PUE 7.1.HRP  High Resolution Scales

SKU #

WL-306-0045

WL-306-0062

WL-306-0041

WL-306-0049

WL-306-0053

WL-306-0047

WL-306-0065

WL-306-0043

Model #

MA 50/1.X2.IC.A

MA 200/1.X2.IC.A  

MA 50.X2.IC.A

MA 110.X2.IC.A  

MA 210.X2.IC.A

MA 50/1.X2.IC.A.WH

MA 200/1.X2.IC.A.WH  

MA 200/1.X2.IC.A.WH  

Maximum capacity(g)

50

200

50

110

200

50

200

200

Readability(mg)

0.1

0.1

1

1

1

1

0.1

1

 

SKU #

WL-306-0051

WL-306-0055

WL-306-0076

WL-306-0079

WL-306-0074

WL-306-0081

WL-306-0083

Model

 #

MA 110.X2.IC.A.WH  

MA 210.X2.IC.A.WH

MA 50/1.X2.IC.A.NS

MA 200/1.X2.IC.A.NS  

MA 50.X2.IC.A.NS

MA 110.X2.IC.A.NS  

MA 210.X2.IC.A.NS

Maximum capacity(g)

110

200

50

200

50

110

210

Readability(mg)

1

1

0.1

0.1

1

1

1

 

MA.X2.IC.A series

is equipped with innovative system: the drying chamber can be opened and closed automatically using button or proximity sensors.
Such solution allows:

  • Maintaining moisture analyzer clean – operator does not touch moisture analyzer’s housing.
  • Remo
  • ving any shocks caused by manual closing of the chamber – the chamber closes automatically and always with the same intensity.
  • Achieving high repeatability of opening and closing the drying chamber.
  • Enhancing drying process automation.
  • Enhancing safety of operation by eliminating contact with hot components of drying chamber.
  • Improving operation ergonomics.

MA.X2.IC.A series features user-friendly colour touchscreen. Free configuration of the control panel can be done by means of hotkeys, customizable information fields and programmable labels. Drying process can be carried out for any temperature and – thanks to databases – particular drying process may be set for a specific product.

Highlights of X2 Series moisture analyzers:

  • Automatic opening and closing of the drying chamber
  • 5” capacitive colour touchpad
  • Modern interface
  • Uncomplicated, intuitive operation
  • Programmable display
  • Drying profiles (standard, mild, step, fast)
  • GLP/GMP printouts-reports
  • Repeatable and customized applications
  • Work optimization due to the use of halogen lamps

Capacity and temperature

MA.X2.IC.A maximum capacity ranges from 50g/0.1mg to 210g/0.1mg. Moisture content is measured with the 0.01% accuracy (0.001 % for samples bigger than 1.5g). The maximum drying temperature is 160˚C (there is an optional  moisture analyzer with 250˚C maximum temperature).

An additional element for moisture analyzers that improves their functionality is a water vapour permeability determination set used in tanning industry for determining hygienic properties of leather.

Databases:

Information system of X2 series moisture analyzers is based on 8 databases, allowing many users to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis

Collected data is registered in 8 databases:

  • Products (up to 5000 products)
  • Users (up to 100 users)
  • Packaging (up to 100 packagings)
  • Customers (up to 1000 customers)
  • Drying programs (up to 200 drying programs)
  • Drying process reports (up to 5000 drying process reports)
  • Ambient conditions (up to 10000 records)
  • Weighings (up to 50000 records)

The results

The results obtained using the moisture analyzer (the final result of the drying process):

  • % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
  • % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
  • % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
  • – the sample mass after drying.

Interfaces

USB interface ensures quick transfer and copying of any results of your work (measurements, reports, databases) to a computer or other moisture analyzer.Remote access to the moisture analyzer allows for online data management.

Cooperation with E2R allows for external data management which in turn increases the efficiency and results to the maximum.

Datasheet

Model No.

MA 50/1.X2.IC.A

MA 200/1.X2.IC.A

MA 50.X2.IC.A

MA 110.X2.IC.A

MA 210.X2.IC.A

MA 50/1.X2.IC.A.WH

MA 200/1.X2.IC.A.WH 

MA 50.X2.IC.A.WH

Metrological parameters

Maximum capacity [Max]

50 g

200

50

110

210

50

200

50

Readability [d]

0.1 mg

0.1 mg

0.1 mg

1 mg

1 mg

0.1 mg

0.1 mg

1 mg

Tare range

-50 g

-200 g

-50 g

-110 g

-210 g

-50 g

-200 g

-50 g

Adjustment

internal (automatic)

Maximum sample weight

50 g

200 g

50 g

110 g

210 g

50 g

200 g

50 g

Heating module

IR emitter

halogen

Moisture content repeatability

+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)

Moisture content readability

0.0001%

0.0001%

0.0001%

0.001%

0.001%

0.0001%

0.0001%

0.001%

Drying temperature range

Max 160°C

Max 160°C

Max 160°C

Max 160°C

Max 160°C

Max 160 °C

Max 160 °C

Max 250 °C

Physical parameters

Leveling system

manual

manual

manual

manual

manual

manual

manual

manual

Display

5” graphic color touchscreen

Weighing chamber

automatic

Maximum sample height

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Weighing pan dimensions

ø90, h= 8 mm

Packaging dimensions

476×381×346 mm

Net weight

5.3 kg

5.3 kg

5.3 kg

5.3 kg

5.4 kg

5.3 kg

5.3 kg

5.3 kg

Gross weight

7 kg

7 kg

7 kg

6.8 kg

6.9 kg

7 kg

7 kg

6.8 kg

Construction

Protection class

IP 43

IP 43

IP 43

IP 43

IP 43

IP 43

IP 43

IP 43

Features of use

Display mode

%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC

Drying method

4 drying profiles (standard, fast, step, mild)

Finish mode

4 modes (automatic, manual, time-defined, user-defined)

Additional functions

sample traceability

Communication interface

Communication interface

 RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®

Electrical parameters

Power supply

100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz

Power consumption

6 W

6 W

6 W

6 W

6 W

6 W

6 W

6 W

Heating module power

450 W

450 W

450 W

450 W

450 W

450 W

450 W

450 W

Environmental conditions

Operating temperature

+10 — +40 °C

SOP – metrological tests

Mass indication control

External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)

Internal adjustment

For .IC models only, GLP report

External adjustment

For all models, GLP report

Drying temperature control

One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer)

Moisture content indication control

Certified MV Test Set

Adjustment

Internal / External adjustment

 Depending on the type of moisture analyzer, GLP report

Drying temperature adjustment

 Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)

 

Model No.

MA 110.X2.IC.A.WH

MA 210.X2.IC.A.NS

MA 50/1.X2.IC.A.NS

MA 200/1.X2.IC.A.NS

MA 50.X2.IC.A.NS

MA 110.X2.IC.A.NS

MA 210.X2.IC.A.NS

Metrological parameters

Maximum capacity [Max]

110 g

210 g

50 g

200 g

50 g

110 g

210 g

Readability [d]

1 mg

1 mg

0.1 mg

0.1 mg

1 mg

1 mg

1 mg

Tare range

-50 g

-210 g

-50 g

-200 g

-50 g

-110 g

-210 g

Adjustment

internal (automatic)

Maximum sample weight

110 g

210 g

50 g

200 g

50 g

110 g

210 g

Heating module

halogen

metal heater

Moisture content repeatability

+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)

Moisture content readability

0.001%

0.001%

0.0001%

0.0001%

0.001%

0.001%

0.001%

Drying temperature range

Max 250 °C

Max 250 °C

Max 160 °C

Max 160 °C

Max 160 °C

Max 160 °C

Max 160 °C

Physical parameters

Leveling system

manual

Display

5” graphic color touchscreen

Weighing chamber

automatic

Maximum sample height

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Weighing pan dimensions

ø90, h= 8 mm

Packaging dimensions

476×381×346 mm

Net weight

5.3 kg

5.3 kg

5.4 kg

5.3 kg

5.3 kg

5.3 kg

5.4 kg

Gross weight

6.8 kg

6.9 kg

6.8 kg

6.8 kg

6.8 kg

6.8 kg

6.9 kg

Construction

Protection class

IP 43

IP 43

IP 43

IP 43

IP 43

IP 43

IP 43

Features of use

Display mode

%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC

Drying method

4 drying profiles (standard, fast, step, mild)

Finish mode

4 modes (automatic, manual, time-defined, user-defined)

Additional functions

sample traceability

Communication interface

Communication interface

RS232¹, USB-A, USB-B, Ethernet, Wi-Fi®

Electrical parameters

Power supply

100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz

Power consumption

6 W

6 W

6 W

6 W

6 W

6 W

6 W

Heating module power

450 W

450 W

450 W

450 W

450 W

450 W

450 W

Environmental conditions

Operating temperature

+10 — +40 °C

SOP – metrological tests

Mass indication control

External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)

Internal adjustment

For .IC models only, GLP report

External adjustment

For all models, GLP report

Drying temperature control

One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer)

Moisture content indication control

Certified MV Test Set

Adjustment

Internal / External adjustment

 Depending on the type of moisture analyzer, GLP report

Drying temperature adjustment

Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)

 

 

*The power supply can be connected to the socket on the back of the balance housing or to the terminal.

MSE Supplies is an authorized distributor for RADWAG.