Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

RADWAG MYA 21.5Y.P Microbalances for Calibration of Pipettes ELLIPSIS – MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

RADWAG MYA 21.5Y.P Microbalances for Calibration of Pipettes ELLIPSIS 5Y SERIES

RADWAG MYA 21.5Y.P Microbalances for Calibration of Pipettes ELLIPSIS 5Y SERIES

SKU: WL-109-0023

  • $ 22,01295
  • Save $ 3,88400


RADWAG MYA 21.5Y.P Microbalances for Calibration of Pipettes ELLIPSIS 5Y SERIES

Buy RADWAG products from MSE Supplies at the best value. 

SKU #

WL-109-0023

Model #

MYA 21.5Y.P

Maximum Capacity (g)

6.1

Readability (µg)

1

 

Digital Weighing Auditor

Ensures that your balance is ready for use. It enables air buoyancy compensation in real-time. What is more, it informs about the need for a balance inspection or a periodic audit of the balance’s accuracy and sensitivity.

10-Inch Display

Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.

Uncompromising User Verification

For the first time ever, the balance will verify the user using a password,
RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.

Ambient Light – An Innovative Way for the Balance to Communicate With the User

The light colour will tell you about status, process results, procedures, or alerts.

Hotspot

Use the balance on any device connected to it. This can be a smartphone, tablet, or computer.

RFID

ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.

Live Note – Note Down Your Conclusions

It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.

Handy Library

This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.

Widgets

Prepared to display what you need most at any given moment.

Automatic Leveling of the Balance ReflexLEVEL System

Instead of manually leveling your scale - level it automatically.
The ReflexLEVEL System saves you time and gives you maximum precision in your measurements.

Smart Min Weight

The balance displays whether the value of the weight you want to weigh is below or above the minimum weight threshold.

21 CFR Part 11

Do you work in the pharmaceutical industry? Do you need a digital signature?
 
We are offering the laboratory balance which as a standalone fully meets the requirements of 21 CFR Part 11/ EU GMP Annex 11.
 
- Full data security
- Electronic signatures
- Validations
- Electronic records
- Audit trails

Modbus TCP/IP

is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrators. 
 
A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.

Two-point adjustment

Adjacency, which takes place at two measurement points instead of one, improves measurement precision over the full weighing range. And what does this mean for you? More accurate measurement.

Datasheet

Model No.

MYA 21.5Y.P

Metrological parameters

Maximum capacity [Max]

21 g

Minimum load

0.1mg

Readability [d]

1 µg

Verification unit [e]

1 mg

Tare range

-21 g

Standard repeatability [5% Max]

1 µg

Standard repeatability [Max]

3 µg

Standard minimum weight (USP)

2 mg

Standard minimum weight (U=1%, k=2)

0.2 mg

Permissible repeatability [5% Max]

1.6 µg

Permissible repeatability [Max]

4 µg

Linearity

±7 µg

Eccentric load deviation

7 µg

Sensitivity time drift

1×10⁻⁶/Year×Rt

Stabilization time

~5 s

Adjustment

internal (automatic)

OIML Class

I

Physical parameters

Leveling system

semi-automatic - LevelSENSING

Display

10″ graphic colour touchscreen

Weighing chamber doors

automatic

Delivery components

Microbalance, terminal, weighing pan, weighing pan shield, glass vessel, evaporation ring, glass lid, additional glass lid, glass lid, power supply, pincette, brush, fabric dust cover.

Weighing chamber dimensions

Ø 90x90 mm

Capacity

11 ml

Weighing pan dimensions

 ø26 mm

Packaging dimensions

750×492×595 mm

Net weight

9.1 kg

Gross weight

16.6 kg

Communication interface

Communication interface

2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot

Electrical parameters

Power supply

Adapter: 100 – 240V AC 50/60Hz 1A; 15V DC 2.4A

Balance: 12 – 15V DC 1.4A max*

Environmental conditions

Operating temperature

+10 — +40 °C

Operating temperature change rate

±0.3°C/1h (±1°C/8h)

Relative humidity

40% — 80%

Relative humidity change rate

±1%/h (±4%/8h)

 

*The power supply can be connected to the socket on the back of the balance housing or to the terminal.