Sodium (Na) Colorimetric Assay Kit

SKU: E-BC-K207-M-96

To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.

Sodium (Na) Colorimetric Assay Kit

SKU # E-BC-K207-M
Detection Instrument Microplate reader (405 nm)
Detection method Colorimetric method


Product Details

Properties

Sample Type Serum, plasma, tissue
Sensitivity 0.02 mmol/L
Detection Range 0.02 - 20 mmol/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 15 min
Precision Average inter-assay CV: 8.400% | Average intra-assay CV: 2.200%
Storage 2-8℃
Valid period 12 months


Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human serum 1
Human plasma 1
Mouse serum 1
Rat plasma 1

 

Note: The diluent is double distilled water. For the dilution of other sample types, please do pretest to confirm the dilution factor

 

Detection Principle

β-galactosidase activated by sodium ions can catalyze o-nitrophenol to produce glycoside and o-nitrophenol. The increase of absorbance is determined at 405 nm, and the content of sodium ion is calculated indirectly.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Chromogenic Agent 5 mL × 1 vial 10 mL × 1 vial 2-8℃, 12 months
shading light
Reagent 2 Enzyme Stock Solution 10 mL × 1 vial 20 mL × 1 vial 2-8℃, 12 months
Reagent 3 Enzyme Reagent Power × 1 vial Power × 2 vials 2-8℃, 12 months
Reagent 4 10 mmol/L Standard 1.6 mL ×1 vial 1.6 mL ×1 vial 2-8℃, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 2.50 9.70 15.60
%CV 2.5 2.1 2.0


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 2.50 9.70 15.60
%CV 8.2 8.5 8.5

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 98%.

Sample 1 Sample 2 Sample 3
Expected Conc. (mmol/L) 4.6 12.5 17.3
Observed Conc. (mmol/L) 4.6 11.8 17.5
Recovery rate (%) 99 94 101

 

Sensitivity

The analytical sensitivity of the assay is0.02 mmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.