Total Antioxidant Capacity (T-AOC) Colorimetric Assay Kit

SKU: E-BC-K136-S-100

To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.

Total Antioxidant Capacity (T-AOC) Colorimetric Assay Kit

SKU # E-BC-K136-S
Detection Instrument Spectrophotometer (520 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms T-AOC
Sample Type Serum, plasma, saliva, urine, tissue, cells
Sensitivity 0.62 U/mL
Detection Range 0.62-145.2 U/mL
Detection Method Colorimetric method
Assay type Quantitative
Assay time 80 min
Precision Average inter-assay CV: 8.200% | Average intra-assay CV: 2.700%
Other instruments required Vortex mixer, Micropipettor, Water bath, Incubator, Centrifuge
Other reagents required Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4)
Storage 2-8℃
Valid period 12 months

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.62-145.2 U/mL).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Mouse liver tissue homogenization 1
10% Mouse lung tissue homogenization 1
Human saliva 1
Human serum 1
Porcine serum 1
Rat plasma 1
HepG2 cells homogenization 1

 

Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).

 

Detection Principle

A variety of antioxidant macromolecules, antioxidant molecules and enzymes in a system can eliminate all kinds of reactive oxygen species and prevent oxidative stress induced by reactive oxygen species. The total level reflect the total antioxidant capacity in the system. Many antioxidants in the body can reduce Fe3+ to Fe2+ and Fe2+ can form stable complexes with phenanthroline substance. The antioxidant capacity (T-AOC) can be calculated by measuring the absorbance at 520 nm.

 

Kit Components & Storage

Item Component Size 1
(50 Assays)
Size 2
(100 Assays)
Storage
Reagent 1 Buffer Solution 6 mL × 1 vial 60 mL × 2 vials 2-8°C, 12 months
Reagent 2 Chromogenic Agent Powder ×1 vial Powder × 2 vials 2-8°C, 12 months, shading light
Reagent 3 Ferric Salt Stock Solution 1.5 mL × 1 vial 1.5 mL × 2 vials 2-8°C, 12 months, shading light
Reagent 4 Ferric Salt Diluent 30 mL × 1 vial 60 mL × 1 vial 2-8°C, 12 months
Reagent 5 Stop Solution 24 mL × 1 vial 24 mL ×1 vial 2-8°C, 12 months
Reagent 6 Clarificant 24 mL × 1 vial 24 mL ×1 vial 2-8°C, 12 months

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (U/mL) 12.50 72.40 126.00
%CV 3.0 2.6 2.5


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/mL) 12.50 72.40 126.00
%CV 8.1 7.9 8.6

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 105%.

Standard 1 Standard 2 Standard 3
Expected Conc. (U/L) 32.8 88.5 108
Observed Conc. (U/L) 33.8 93.8 114.5
Recovery rate (%) 103 106 106

 

Sensitivity

The analytical sensitivity of the assay is 0.62 U/mL. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.