Total Antioxidant Status (TAS) Colorimetric Assay Kit

SKU # E-BC-K801-M
Detection Instrument Microplate reader (650 nm-670 nm, optimum wavelength: 660 nm)
Detection method: Colorimetric method


Product Details

Properties

Synonyms TAS
Sample type Serum, plasma, urine, cellular supernatant, animal, plant tissue
Sensitivity 0.23 mmol Trolox Equiv./L
Detection range 0.23-2 mmol Trolox Equiv./L
Detection method Colorimetric method
Assay type Quantitative
Assay time 30 min
Precision Average inter-assay CV: 7% | Average intra-assay CV: 4.600%
Other instruments required Microplate centrifuge, Micropipettor, Water bath
Other reagents required 60% Ethanol
Storage -20℃
Valid period 12 months


Images

X Zhao et al investigate the function of quercetin for reducing ethanol-induced hepatocyte pyroptosis. Total antioxidants status (TAS) of human L02 cell was determined using TAS colorimetric assay kit (E-BC-K801-M).

Different subscript letters indicate significant differences among the groups. (P<0.05)


Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.23-2 mmol Trolox Equiv. /L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Mouse liver tissue homogenate 1
10% Rat liver tissue homogenate 1
10% Rat lung tissue homogenate 1
Molt4 cellar supernatant 1
Human urine 8-10
Mouse serum 1
Human serum 1
Human saliva 1

 

Note: The diluent is 60% Ethanol.

 

Detection Principle

ABTS is oxidized to green ABTS•+ by appropriate oxidant, which can be reduced to colorless ABTS in the presence of antioxidants. The TAS of the sample can be determined and calculated by measuring the absorbance of ABTS•+ at 660 nm. Trolox is an analog of VE and has a similar antioxidant state to that of VE. Trolox is used as a reference substance for total antioxidant status.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Buffer Solution 15 mL × 1 vial 30 mL × 1 vial -20℃, 12 months
Reagent 2 Chromogenic Agent 5 mL ×1 vial 5 mL ×1 vial -20℃, 12 months,
shading light
Reagent 3 2 mmol/L Standard 2 mL ×1 vial 4 mL ×1 vial -20℃, 12 months,
shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces


Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.


Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol Trolox Equiv./L) 0.87 1.05 1.46
%CV 4.8 4.5 4.5


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol Trolox Equiv./L) 0.87 1.05 1.46
%CV 6.8 7.3 6.9


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 99%.


Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.7 1.35 1.75
Observed Conc. (mmol/L) 0.7 1.3 1.7
Recovery rate(%) 101 99 97


Sensitivity

The analytical sensitivity of the assay is 0.23 mmol Trolox Equiv./L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mmol/L) 0 0.4 0.8 1.2 1.4 1.6 1.8 2
Average OD 1.196 0.978 0.818 0.664 0.583 0.516 0.436 0.368
Absoluted OD 0.000 0.217 0.378 0.532 0.612 0.680 0.759 0.827