Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Total Iron Binding Capacity (TIBC) Colorimetric Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

Total Iron Binding Capacity (TIBC) Colorimetric Assay Kit

SKU: E-BC-K071-S-50

To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.

Total Iron Binding Capacity (TIBC) Colorimetric Assay Kit

SKU # E-BC-K071-S
Detection Instrument Spectrophotometer (520 nm)
Detection Method Colorimetric method


Product Details

Properties

Synonyms TIBC
Sample Type Serum
Sensitivity 0.03 mg/L
Detection Range 0.03-50 mg/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 50 min
Precision Average inter-assay CV: 4.700% | Average intra-assay CV: 3.400%
Other instruments required Micropipettor, Water bath, Vortex mixer, Centrifuge
Other reagents required Normal saline (0.9% NaCl)
Storage 2-8℃
Valid period 12 months


Images

R M Adel et al investigate the destructive effect of iron overload by silver nanocomposite. Total iron binding capacity (TIBC) in rat serum was determined using TIBC colorimetric assay kit (E-BC-K071-S).

Table. Effect of iron sucrose administration and subsequent co-treatments of DFX with Tr-CA and Ag@Tr-CA on serum Fe, TIBC, ferritin and Tf levels in different groups. Mean ± S.E.M. and % of change.

Fe μmol/1 % of change TIBC μmol/1 % of change Ferritin ng/mL % of change Tf ng/mL % of change
Group 1 (control) 19.10 ± 0.64  ___ 51.18 ± 0.27 ___ 4.50 ± 0.12  ___ 10.60 ± 0.09  ___
Group 2 (iron sucrose) 56.23a ± 2.94 194.40% 87.70a ± 1.60 71.36% 6.833a ± 0.47 51.78% 23.80a ± 1.97 124.53%
Group 3 (DFX) 19.66b ± 0.31 2.93% 60.40a,b ± 1.33 18.01% 5.33b ±0.26 18.44% 14.30a,b ± 0.40 34.91%
Group 4 (DFX + Tr-CA) 21.23b ± 0.63 11.15% 60.43a,b ± 2.52  18.07% 4.70b ± 0.21  4.44% 15.23a,b ± 0.13 43.68%
Group 5 (DFX + Ag@Tr-CA) 20.37b ± 0.47 6.65% 56.93a,b ± 2.42 11.23% 4.73b ± 0.27 5.11% 16.43a,b ± 0.92 55%

By ANOVA, P < 0.05, LSD Test. a = P < 0.05 vs Group 1. b = P < 0.05 vs Group 2. a & b = The mean difference is significant at the 0.05 level.

TIBC was significantly changed after treated.

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.03-50 mg/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human serum 1
Rat serum 1
Porcine serum 1
Rabbit serum 1
Chicken serum 1
Cynomolgus monkey serum 1

 

Note: The diluent is double distilled water or normal saline (0.9% NaCl).

 

Detection Principle

The excess iron is added to the serum to bind all the ferritin in the serum, and the excess iron is adsorbed by adding the iron adsorbent. The iron bind with the ferritin is separated from the protein by the action of acid solution and reductant. Fe3+ in serum is reduced to Fe2+, Fe2+ binds with bipyridine to form pink complex. In a certain range, the amount of TIBC is positively correlated with the depth of color. The iron content measured is, minus serum iron value, which is called unsaturated iron binding force. Total iron binding capacity minus serum iron value is unsaturated iron binding capacity (UIBC).

 

Kit Components & Storage

Item Component Size (50 Assays) Storage
Reagent 1 100 mg/L Iron Standard Stock Solution 7 mL ×1 vial 2-8℃, 12 months
Reagent 2 Chromogenic Agent A Powder × 2 vials 2-8℃, 12 month shading light
Reagent 3 Chromogenic Agent B Powder × 2 vials 2-8℃, 12 month shading light
Reagent 4 Chromogenic Agent C 60 mL × 2 vials 2-8℃, 12 months
Reagent 5 Iron Absorbent 50 mg × 50 vials 2-8℃, 12 months

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.


Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (mg/L) 3.50 24.60 44.50
%CV 3.6 3.2 3.4


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mg/L) 3.50 24.60 44.50
%CV 4.5 4.7 4.9

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 100%.


Sample 1 Sample 2 Sample 3
Expected Conc. (mg/L) 13.8 34.7 45
Observed Conc. (mg/L) 13.7 34.0 46.4
Recovery rate (%) 99 98 103


Sensitivity

The analytical sensitivity of the assay is 0.03 mg/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

The OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mg/L) 0 5 10 20 30 40 50
Average OD 0.001 0.130 0.253 0.515 0.755 1.034 1.283
Absoluted OD 0 0.129 0.252 0.514 0.754 1.033 1.282