Total Phenols Colorimetric Assay Kit (Plant Samples)

SKU: E-BC-K354-S-200

To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.

Total Phenols Colorimetric Assay Kit (Plant Samples)

SKU # E-BC-K354-S
Detection Instrument Spectrophotometer (760 nm)
Detection method Colorimetric method


Product Details

Properties

Sample type Plant tissue
Sensitivity 0.73 μg/mL
Detection range 0.73-150 μg/mL
Detection Method Colorimetric method
Assay type Quantitative
Assay time 60 min
Precision Average inter-assay CV: 2.500% | Average intra-assay CV: 1.900%
Other instruments required Micropipettor, Vacuum dryer, Vortex mixer, Ultrasonic cell grinder, Crusher
Other reagents required 60% Ethanol
Storage 2-8℃
Valid period 12 months


Detection Principle

Under alkaline conditions, tungsten-molybdenum acid can be reduced by phenols and produce blue compounds, which has a characteristic absorption peak at 760 nm. The content of total phenols in sample can be calculated indirectly by measuring the absorbance at 760 nm.

 

Kit Components & Storage

Item Component Size 1
(100 assays)
Size 2
(200 assays)
Storage
Reagent 1 Folin Phenol Reagent 60 mL × 1 vial 60 mL × 2 vial 2-8°C, 12 months shading light
Reagent 2 Alkali Powder × 2 vials Powder × 4 vials 2-8°C, 12 months
Reagent 3 O-dihydroxybenzene 10 mg ×4 vials 10 mg × 8 vials 2-8°C, 12 months
shading light

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (μg/mL) 9.40 48.50 96.20
%CV 2.3 1.8 1.6


Inter-assay Precision

Three human serum samples were assayed 17 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (μg/mL) 9.40 48.50 96.20
%CV 2.1 2.6 2.8


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 101%.


Standard 1 Standard 2 Standard 3
Expected Conc. (μg/mL) 32.5 84.5 126
Observed Conc. (μg/mL) 32.2 87.0 127.3
Recovery rate (%) 99 103 101

 

Sensitivity

The analytical sensitivity of the assay is 0.73 μg/mL. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.


Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (μg/mL) 0 40 60 80 100 120 150
Average OD 0.001 0.209 0.309 0.412 0.506 0.599 0.737
Absoluted OD  0 0.208 0.308 0.411 0.505 0.598 0.736