Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Aldehyde Dehydrogenase (ALDH) Fluorometric Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Aldehyde Dehydrogenase (ALDH) Fluorometric Activity Assay Kit

SKU: E-BC-F044-96

  • £24100
  • Save £4200



Aldehyde Dehydrogenase (ALDH) Fluorometric Activity Assay Kit

SKU # E-BC-F044
Detection Instrument Fluorescence microplate reader (Ex/Em=535 nm/587 nm)
Detection Method Fluorescence method


Product Details

Properties

Synonyms ALDH
Sample Type Serum (plasma), animal tissue, cell
Sensitivity 0.06 μmol/L
Detection Range 0.06–3 μmol/L
Detection Method Fluorescence method
Assay Time 20 min
Precision Inter-assay CV: 8.4% | intra-assay CV: 4%
Storage This product can be stored at -20°C for 12 months with shading light.
Valid period 12 months

 

Dilution Of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Rat liver tissue homogenate 150-160
10% Mouse kidney tissue homogenate 90-150
10% Mouse liver tissue homogenate 150-180
10% Mouse lung tissue homogenate 60-90
10% Mouse brain tissue homogenate 30-40
10% Mouse spleen tissue homogenate 60-150
Mouse plasma 3-5
Jurkat cell 8-12


The diluent is normal saline (0.9% NaCl) or double distilled water. For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Detection Principle

The detection principle of this kit is that the substrate under the action of aldehyde dehydrogenase transforms NAD+ into NADH, NADH reacts with the fluorescent probe to form fluorescent substance under the action of enzymes. The activity of ALDH can be calculated by measuring the fluorescence intensity at the excitation wavelength of 535 nm and the emission wavelength of 587 nm.

 

Kit Components & Storage

Item Component Size (96 T) Storage
Reagent 1 Buffer Solution 20 mL ×1 vial -20℃, 12 months
Reagent 2 Coenzyme Powder ×2 vials -20℃, 12 months shading light
Reagent 3 Substrate 0.3 mL ×1 vial -20℃, 12 months shading light
Reagent 4 Chromogenic Agent 0.2 mL ×1 vial -20℃, 12 months shading light
Reagent 5 Enzyme Reagent Powder ×2 vials -20℃, 12 months shading light
Reagent 6 Standard Powder ×2 vials -20℃, 12 months shading light
Black Microplate 96 wells No requirement
Plate Sealer 2 pieces


Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.


    Technical Data:

    Parameter:

    Intra-assay Precision

    Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

    Parameters Sample 1 Sample 2 Sample 3
    Mean (μmol/L) 0.10 1.50 2.30
    %CV 4.2 3.8 4.0

     

    Inter-assay Precision 

    Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

    Parameters Sample 1 Sample 2 Sample 3
    Mean (μmol/L) 0.10 1.50 2.30
    %CV 8.5 7.9 8.8


    Recovery

    Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 100%.


    Standard 1 Standard 2 Standard 3
    Expected Conc. (μmol/L) 0.8 1.5 2.5
    Observed Conc. (μmol/L) 0.8 1.5 2.5
    Recovery rate (%) 101 99 100

     

    Sensitivity

    The analytical sensitivity of the assay is 0.06 μmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

     

    Standard Curve:

    As the fluorescence value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

    Concentration (μmol/L) 0 0.6 0.9 1.2 1.8 2.4 2.7 3
    Fluorescence value 361 997 1225 1506 2025 2756 2963 3309
    345 968 1256 1517 2059 2680 2963 3322
    Average fluorescence value 353 983 1241 1512 2042 2718 2963 3316
    Absoluted fluorescence value 0 630 888 1159 1689 2365 2610 2963