α-Amylase and β-Amylase Activity Assay Kit

SKU: E-BC-K006-M-500

  • £26000
  • Save £4600


α-Amylase and β-Amylase Activity Assay Kit

SKU # E-BC-K006-M
Detection Instrument Microplate reader(535 nm-540 nm, optimum wavelength: 540 nm)
Detection Method Colorimetric method


Product Details

Properties

Sample Type Serum, plasma, saliva, tissue
Sensitivity 0.008 U/mL
Detection Range 0.01-0.56 U/mL
Detection Method Colorimetric method
Assay Time 30 min
Precision Inter-assay CV: 3.6% | intra-assay CV: 2.8%
Storage This product can be stored at 2~8°C for 12 months with shading light.
Valid period 12 months

 

Dilution Of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human plasma 10-15
Human serum 10-15
Human saliva 15-25
Mouse serum 15-25
Rat serum 15-25
1% Corn grain tissue homogenate 2-5


The diluent is double distilled water. For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Detection Principle

The reducing sugar reacts with 3,5-dinitrosalicylic acid under heating conditions to produce a brown-red substance. Amylase activity can be calculated by measuring the OD value at 540 nm.


Kit Components & Storage

Item Component Size (96 T) Storage
Reagent 1 Substrate 10 mL ×1 vial 2-8°C, 12 months
Reagent 2 Chromogenic Agent 2 20 mL × 1 vial 2-8°C, 12 months, shading light
Reagent 3 10 mg/mL Standard 1.5 mL × 1 vial 2-8°C, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces


Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.


    Technical Data:

    Parameter:

    Intra-assay Precision

    Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

    Parameters Sample 1 Sample 2 Sample 3
    Mean (U/mL)
    0.08 1.40 0.25
    %CV 3.2 2.4 2.8

     

    Inter-assay Precision

    Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

    Parameters Sample 1 Sample 2 Sample 3
    Mean (U/mL)
    0.08 1.40 0.25
    %CV 3.0 4.0 3.8


    Recovery

    Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 97%.


    Standard 1 Standard 2 Standard 3
    Expected Conc. (mg/mL) 0.3 0.7 1.1
    Observed Conc. (mg/mL) 0.3 0.7 1.1
    Recovery rate (%) 99 95 97

     

    Sensitivity

    The analytical sensitivity of the assay is 0.008 U/mL. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

     

    Standard Curve:

    As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

    Concentration (mg/mL) 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
    OD value 0.144 0.310 0.483 0.688 0.829 1.016 1.224 1.361
    0.144 0.301 0.486 0.684 0.840 1.013 1.164 1.356
    Average OD 0.144 0.305 0.484 0.686 0.834 1.015 1.194 1.359
    Absoluted OD 0.000 0.161 0.341 0.542 0.691 0.871 1.050 1.215