Cysteine (Cys) Colorimetric Assay Kit

SKU: E-BC-K352-M-96

  • £26300
  • Save £4600



Cysteine (Cys) Colorimetric Assay Kit

SKU # E-BC-K352-M
Detection Instrument Microplate reader (600-620 nm, optimum wavelength: 600 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms Cys
Sample type Serum, plasma, animal tissue, cells
Sensitivity 0.03 mmol/L
Detection range 0.07-2.0 mmol/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 30 min
Precision Average inter-assay CV: 1.300% | Average intra-assay CV: 1.100%
Other instruments required Micropipettor, Centrifuge, Water bath, Incubator, Vortex mixer
Other reagents required Phosphoric acid
Storage 2-8℃
Valid period 12 months


Images

F K Coban et al investigate the acetaminophen-induced nephrotoxicity suppressed by boric acid. Cysteine (CYS) levels in rat serum were determined using CYS colorimetric assay kit (E-BC-K352-M).

The concentration of cysteine was reduced by adding boric acid with dose dependent.

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.07-2.0 mmol/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human serum 1
Mouse serum 1
10% Rat lung tissue homogenate 1
10% Mouse heart tissue homogenate 1
10% Rat brain tissue homogenate 1

 

Note: The diluent is reagent 1.

 

Detection Principle

Phosphotungstic acid can be reduced by Cys and form tungsten blue, which has an absorption peak at 600 nm. Cys content can be calculated with the absorbance at 600 nm.


Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Acid Reagent 60 mL × 1 vial 60 mL × 2 vials 2-8°C, 12 months
shading light
Reagent 2 Buffer Solution 7 mL × 1 vial 15 mL × 1 vial 2-8°C, 12 months
Reagent 3 Chromogenic Agent 6 mL × 1 vial 12 mL × 1 vial 2-8°C, 12 months
shading light
Reagent 4 Standard Powder × 1 vial Powder × 1 vial 2-8°C, 12 months
shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.42 1.05 1.50
%CV 1.4 1.2 0.7


Inter-assay Precision

Three human serum samples were assayed 17 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.42 1.05 1.50
%CV 0.9 1.4 1.6


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 94%.


Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.185 0.62 1.3
Observed Conc. (mmol/L) 0.2 0.6 1.2
Recovery rate (%) 95 92 95

 

Sensitivity

The analytical sensitivity of the assay is 0.03 mmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.


Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mmol/L) 0.00 0.125 0.25 0.50 0.75 1.00 1.50 2.00
OD value 0.038 0.046 0.066 0.092 0.122 0.149 0.206 0.266
0.038 0.046 0.061 0.091 0.120 0.149 0.212 0.268
Average OD 0.038 0.046 0.064 0.092 0.121 0.149 0.209 0.267
Absoluted OD  0.000 0.008 0.026 0.054 0.083 0.111 0.171 0.229