Ferrous Iron Colorimetric Assay Kit

SKU: E-BC-K304-S-100

To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.

Ferrous Iron Colorimetric Assay Kit

SKU # E-BC-K304-S
Detection Instrument Spectrophotometer (520 nm)
Detection method Colorimetric method


Product Details

Properties

Sample type Serum, plasma, animal tissue
Sensitivity 0.08 mg/L
Detection range 0.08-20 mg/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 45 min
Precision Average inter-assay CV: 3.200% | Average intra-assay CV: 3%
Other instruments required Test tubes, Vortex Mixer, Centrifuge, Water bath, Test tubes, Vortex Mixer, Centrifuge, Water bath
Storage 2-8℃
Valid period 12 months


Images

T Tong et al developed a novel ferrous sulfide nanoparticles for inhibiting porcine reproductive and respiratory syndrome virus. Ferrous ion levels in cell were determined using ferrous ion colorimetric assay kit (E-BC-K304-S).

The administration of Fe nanoparticle significantly increased the ferrous level in cells with dose dependent.

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.08-50 mg/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human plasma 1
Human serum 1
10% Rat liver tissue homogenate 1
10% Epipremnum aureum homogenate 1

 

Note: The diluent is double distilled water).

 

Detection Principle

Under the action of acidic solution and reductant, ferric ions can be separated from transferrin in serum, and reduced into ferrous ions (Fe2+). The latter then bind to bipyridine and form pink complexes. The concentration of iron can be calculated by measuring the OD value at 520 nm indirectly.


Kit Components & Storage

Item Component Size 1
(50 assays)
Size 2
(100 assays)
Storage
Reagent 1 FeSO4·7H2O Power Powder × 1 vial Powder × 2 vial 2-8°C, 12 months
shading light
Reagent 2 Chromogenic Agent A Powder × 2 vials Powder × 4 vials 2-8°C, 12 months
shading light
Reagent 3 Chromogenic Agent B 50 mL × 2 vials 50 mL × 4 vials 2-8°C, 12 months

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (mg/L) 1.50 9.70 13.20
%CV 3.4 2.9 2.7


Inter-assay Precision

Three human serum samples were assayed 17 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mg/L) 1.50 9.70 13.20
%CV 2.9 3.3 3.4


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 97%.

Parameters Standard 1 Standard 2 Standard 3
Expected Conc. (mg/L) 2.5 11.6 17.4
Observed Conc. (mg/L) 2.5 11.0 16.9
Recovery rate (%) 99 95 97


Sensitivity

The analytical sensitivity of the assay is 0.08 mg/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.


Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration
(μmol/L)
0 2 4 5 10 15 20
Average OD 0.000 0.040 0.062 0.097 0.179 0.271 0.377
Absoluted OD 0.000 0.040 0.062 0.097 0.179 0.271 0.377