Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Fluoride Resistant Acid Phosphatase (FRAP) Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Fluoride Resistant Acid Phosphatase (FRAP) Activity Assay Kit

SKU: E-BC-K872-M-96

  • £12500
  • Save £2200



Fluoride Resistant Acid Phosphatase (FRAP) Activity Assay Kit

SKU # E-BC-K872-M
Detection Instrument Microplate reader (390-415 nm, optimum wavelength: 405 nm)
Detection method: Colorimetric method


Product Details

Properties

Synonyms FRAP
Sample type Serum (plasma), cells and animal tissue samples
Sensitivity 0.61 U/L
Detection range 0.61 - 49.37 U/L
Detection method Colorimetric method
Assay type Enzyme Activity
Assay time 25 min
Precision Average inter-assay CV: 8% | Average intra-assay CV: 3.600%
Other instruments required Incubator(37℃)
Other reagents required Double distilled water, Normal saline (0.9% NaCl)
Storage -20℃
Valid period 12 months



Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Mouse liver tissue homogenate 3-7
10% Mouse kidney tissue homogenate 3-7
10% Mouse heart tissue homogenate 3-7
10% Mouse lung tissue homogenate 3-7
Rat plasma 5-7
Human serum 1-3
Bovine serum 1-3
1×106 HL-60 cell 1
1×106 293T cell 1


Note: The diluent is normal saline (0.9% NaCl). For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Detection Principle

Fluoride resistant acid phosphatase (FRAP) is not inhibited by fluoride ions. It catalyzes the substrate to produce p-nitrophenol, which has a maximum absorption peak at 405 nm. The activity of FRAP can be calculated by measuring the OD value at 405 nm.

 

Kit Components & Storage

Item Component Size (96 T) Storage
Reagent 1 Buffer Solution 20 mL × 1 vial -20°C, 12 months
Reagent 2 Fluoride Ion Solution 0.5 mL × 1 vial -20°C, 12 months
Reagent 3 Substrate Solution 1 mL × 1 vial -20°C, 12 months, shading light
Reagent 4 Chromogenic Agent 14 mL × 1 vial -20°C, 12 months
Reagent 5 10 mmol/L Standard Solution 1 mL ×1 vial -20°C, 12 months, shading light

Microplate 96 wells No requirement

Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 3.50 18.40 36.70
%CV 3.8 3.5 3.5


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 3.50 18.40 36.70
%CV 7.6 8.2 8.2


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 102%.


Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.13 0.25 0.37
Observed Conc. (mmol/L) 0.1 0.3 0.4
Recovery rate(%) 101 104 101

 

Sensitivity

The analytical sensitivity of the assay is 0.61 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mmol/L) 0 0.1 0.15 0.2 0.3 0.35 0.4 0.5
Average OD 0.054 0.148 0.201 0.254 0.351 0.406 0.455 0.544
Absoluted OD 0 0.094 0.147 0.2 0.297 0.352 0.401 0.490