Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Lipoxygenase (LOX) Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Lipoxygenase (LOX) Activity Assay Kit

SKU: E-BC-K861-M-96

  • £26200
  • Save £4600



Lipoxygenase (LOX) Activity Assay Kit

SKU # E-BC-K861-M
Detection Instrument Microplate reader (270-290 nm, optimum wavelength: 280 nm)
Detection method
Colorimetric method


Product Details

Properties

Synonyms LOX
Sample type Plant samples
Sensitivity 5 U/L
Detection range 5-339.5 U/L
Detection method Colorimetric method
Assay type Enzyme Activity
Assay time 15 min
Precision Average inter-assay CV: 5% | Average intra-assay CV: 4%
Other instruments required Centrifuge, Incubator (37°C), Homogenizer
Other reagents required Double distilled water, Tween-20
Storage 2-8℃
Valid period 12 months

 

Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Long bean 1
10% Green soy bean 2-5


Note: The diluent is extraction solution. For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Detection Principle

LOX can catalyze linoleic acid oxidation, the oxidation product has the specific absorption peak at 280 nm. The activity of LOX can be calculated by measuring the change of absorbance value at 280 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Extraction Solution 50 mL × 1 vial 50 mL × 2 vials 2-8℃, 12 months
Reagent 2 Buffer Solution 15 mL × 1 vial 30 mL × 1 vial 2-8℃, 12 months
Reagent 3 Substrate 0.1mL × 1 vial 0.1mL × 1 vial 2-8℃, 12 months, shading light
UV Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain ;sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

 

Three long bean samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 8.40 68.50 188.00
%CV 4.3 4.1 3.6


Inter-assay Precision

Three long bean samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 8.40 68.50 188.00
%CV 4.8 5.2 101


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 99%.


Sample 1 Sample 2 Sample 3
Expected Conc. (U/L) 87.5 169 284
Observed Conc. (U/L) 86.6 163.9 286.8
Recovery rate(%) 99 97 101

 

Sensitivity

The analytical sensitivity of the assay is 0.036 mmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.