MSE PRO Ion Chromatography System Model 4
SKU: MA2609
To better serve you, we would like to discuss your specific requirement.
Please Contact Us for a quote.
MSE PRO™ Ion Chromatography System Model 4
Features
- Cation and Anion Dual-Channel System: Both channels operate independently, ensuring no interference between them, allowing simultaneous detection of cations and anions.
- Eluent Thermal Buffer System: Preheats the eluent before it enters the columns, preventing bubble formation caused by rapid heating.
- Built-In Low-Pressure Degassing Technology: Eliminates bubble interference, enhancing system stability.
- Advanced Chromatograph Column Series: Offers a full range of columns capable of detecting ions with diverse compositions.
-
Exceptional Performance: Designed to support all your application needs efficiently
Instrument Highlight
Major Standards
I. Ion Chromatographic Pump
- Type: High-pressure, low-pulse, double-plunger series pump
- Pressure Range: 0~42 MPa
- Flow Range: 0.001~9.999 mL/min
- Pressure Accuracy: ≤0.1 MPa
- Flow Accuracy (Setting Error): RSD ≤0.1%
II. Digital Temperature-Control Detection System
Conductivity Detector
- Structure: Temperature-controlled, bipolar conductivity detector
- Detection Mode: Double conductivity detection
- Conductance Cell Size: ≤0.8 µL
- Output Voltage: -5000~5000 mV (adjustable)
- Measurement Range: 0~30000 µS/cm (10 selectable levels)
- Resolution: ≤0.025 nS
- Conductance Cell Temperature: 5~50°C (adjustable)
- Constant Temperature Accuracy: ±0.01°C
- Baseline Noise: ≤0.6% FS
- Baseline Drift: ≤2.0% FS
- Qualitative Repeatability: ≤1%
- Quantitative Repeatability: ≤1%
III. Flow System
- Pipeline Material: Entirely made of PEEK plastic materials
- Six-Way Valve: Rheodyne electromagnetic six-way valve (USA) with compression resistance of 7000 psi and automatic signal collection capability.
IV. Analytical Capability
1. High-Capacity Anion Column
- Compatible with pH 0~14 and organic solvents.
- Capable of analyzing multiple ions simultaneously, including:
- F⁻, Cl⁻, NO₂⁻, PO₄³⁻, Br⁻, NO₃⁻, SO₄²⁻, ClO₂⁻, BrO₃⁻, ClO₃⁻.
2. High-Capacity Cation Column
- Capable of separating and analyzing ions such as:
- Lysine, Li⁺, Na⁺, NH₄⁺, K⁺, Mg²⁺, Ca²⁺, Sr²⁺, Ba²⁺, and choline chloride.
3. Detector Capabilities
- Supports the detection of various transition metallic ions, heavy metallic ions, and special ions.
V. Performance Metrics
- Analysis Repeatability: ≤1.0% (e.g., SO₄²⁻, Na⁺)
- Linear Range: ≥10³
-
Minimum Detection Concentrations:
- Cl⁻: ≤0.1 ppb
- Na⁺: ≤5 ppb
Specification
Built-in Eluent Generator | Eluent Types | KOH/NaOH/LiOH/MSA |
Eluent Concentration Range | 0.1-100mM | |
Concentration Increment | 0.1mM | |
Flow Rate Range | 0.1-5.0 mL/min | |
Maximum Pressure | 30 MPa | |
Minimum Pressure | 5 MPa | |
Vacuum Degasser | Vacuum Degree | -70 kPa |
Internal Volume | 300 µL | |
Maximum Flow Rate | 10 mL/min | |
Degassing Efficiency | 1.0 mL/min (90%) | |
Degassing Volume | 7.5 mL | |
Sensor | Leakage Sensor | Standard configuration |
Gas-liquid Separator | Gas-liquid Separator Configuration | One (Standard configuration) |
Flow Path | Material | Chemically inert, metal-free PEEK flow paths, compatible with aqueous eluents of pH 0-14 and reversed-phase solvents |
Pump | Type | High-pressure and low-pulse two-piston tandem advection pump |
Maximum Pressure | 42 MPa | |
Flow Rate Range | 0.001-9.999 mL/min | |
Pressure Ripple | ≤0.5% | |
Flow Precision | ≤0.1% | |
Flow Accuracy | ≤0.1% | |
External Diameter of the Tube | 1/16 inch | |
Column Heater | Operating Temperature Range | Ambient +5 to 60°C |
Controlling Temperature Accuracy | ±0.1°C | |
Temperature Stability | ≤0.1°C/h | |
Column Supported | 2, 3, 4 and 5 mm ID. Maximum length 250 mm analytical column with 50 mm guard column |
|
Conductivity Detector | Type | Auto-range conductivity detector |
Cell Volume | ≤0.8 µL | |
Detection Range | 0~50000 µS/cm | |
Resolution | ≤0.0020 nS/cm | |
Output Voltage | -6000~+6000 mV (adjustable) | |
Electronic Noise | 0.02 nS | |
Baseline Noise | ≤0.0005 µS/cm | |
Baseline Drift | ≤0.005 µS | |
Operating Temperature Range | Ambient +5°C~60°C | |
Controlling Temperature Accuracy | ±0.01°C | |
Temperature Compensation | 1.7%/°C | |
Maximum Pressure | 10.0 MPa | |
Linear Range | ≥10³ | |
Instrument Linearity | ≥0.999 | |
Quantitative Repeatability | ≤0.5% | |
Qualitative Repeatability | ≤0.2% | |
Minimum Detectable Concentration | Cl⁻ ≤0.0004 µg/mL, Li⁺ ≤0.0001 µg/mL | |
Suppressor | Type | Self-Regeneration electrolytic micro-membrane suppressor |
Maximum Pressure | 6.0 MPa | |
Non-Suppressed Chromatography | Yes/support | |
Void Volume | <40 µL (4mm), <15 µL (2mm) | |
Power Supply | 350W | |
External Size(L*W*H*) | 500×500×760 mm | |
Net Weight (KG) | 48 | |
Gross Weight (KG) | 73 |