Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Sialic Acid (SA) Colorimetric Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Sialic Acid (SA) Colorimetric Assay Kit

SKU: E-BC-K068-M-500

  • £41400
  • Save £7300



Sialic Acid (SA) Colorimetric Assay Kit

SKU # E-BC-K068-M
Detection Instrument Microplate reader (510-570 nm, optimum wavelength: 560 nm)
Detection Method Colorimetric method


Product Details

Properties

Synonyms SA
Sample Type Serum, plasma, saliva, urine, hydrothorax, tissue
Sensitivity 0.03 mmol/L
Detection Range 0.03-7 mmol/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 40 min
Precision Average inter-assay CV: 6.100% | Average intra-assay CV: 4%
Other instruments required Micropipettor, Centrifuge, Incubator, Water bath, Vortex mixer
Other reagents required Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4)
Storage Reagent 1: -20℃, Reagent 2: 2-8℃
Valid period 12 months


Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.03-7 mmol/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human serum 1
Rat serum 1
Mouse serum 1
Porcine serum 1
Human plasma 1
Rat plasma 1
Mouse plasma 1
Human saliva 1
Human urine 1
Human hydrothorax 1
10% Plant tissue homogenate 1
10% Mouse heart tissue homogenate 1
10% Mouse liver tissue homogenate 1
10% Mouse kidney tissue homogenate 1
10% Mouse lung tissue homogenate 1
10% Mouse brain tissue homogenate 1

 

Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).

 

Detection Principle

Sialic acid forms a purplish red complex with methyl resorcinol in the presence of oxidant. And the absorbance conforms to Lambert-Beer's law. The content of sialic acid can be calculated by measuring the OD value at 560 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 8 mmol/L SA Standard 1 mL × 1 vial 1 mL × 2 vials -20℃, 12 months, shading light
Reagent 2 Chromogenic Agent 30 mL × 1 vial 30 mL × 2 vials 2-8℃, 12 months, shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces


Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

 

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 1.30 4.60 5.80
%CV 2.5 2.0 2.1


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 1.30 4.60 5.80
%CV 6.5 6.3 6.7


Recovery

 

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 102%.


Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 1.5 3.8 5.4
Observed Conc. (mmol/L) 1.5 3.9 5.5
Recovery rate (%) 101 103 102


Sensitivity

The analytical sensitivity of the assay is 0.03 mmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mmol/L) 0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
Average OD 0.043 0.104 0.177 0.255 0.332 0.413 0.495 0.559
Absoluted OD 0 0.061 0.134 0.212 0.289 0.370 0.452 0.516