Thiobarbituric Acid Reactants (TBARS) Colorimetric Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Thiobarbituric Acid Reactants (TBARS) Colorimetric Assay Kit

SKU: E-BC-K298-M-500

  • £32500
  • Save £5700


Thiobarbituric Acid Reactants (TBARS) Colorimetric Assay Kit

SKU # E-BC-K298-M
Detection Instrument Microplate reader (530-540 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms TBARS
Sample type Serum, plasma, animal tissue
Sensitivity 0.85 μmol/L
Detection range 2.6-100 μmol/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 80 min
Precision Average inter-assay CV: 7.100% | Average intra-assay CV: 4.300%
Other instruments required Vortex mixer, Micropipettor, Water bath
Other reagents required Acetic acid, Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4)
Storage 2-8℃
Valid period 12 months


Images

KW Parn et al investigate the anti-hypertension effect of epigallocatechin gallate. Thiobarbituric acid reactants (TBARS) level in rat liver was determined using TBARS colorimetric assay kit (E-BC-K298-M).

High dose EGCG increased the concentration of TBARS in rat liver. (*P<0.05)

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (2.6-100 μmol/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human serum 1
Rat serum 1
10% Mouse brain tissue homogenization 1
Human serum 1
Rat serum 1
10% Rat liver tissue homogenization 1

 

Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).

 

Detection Principle

TBARS and TBA can react under high temperature and acid conditions and then form a pink compound, the concentration of which is linearly related to the concentration of TBARS in the sample. The TBARS concentration can be calculated by measuring the OD values at 530-540 nm.


Kit Components & Storage

Item Component Size 1 (48 T) Size 2 (96 T) Storage
Reagent 1 Clarificant 12 mL × 1 vial 12 mL × 1 vial 2-8°C, 12 months
Reagent 2 Acid Reagent 6 mL × 1 vial 12 mL × 1 vial 2-8°C, 12 months
Reagent 3 TBA Reagent Powder × 1 vial Powder × 1 vial 2-8°C, 12 months
shading light
Reagent 4 20 μmol/L Standard 5 mL × 1 vial 5 mL × 1 vial 2-8℃, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (μmol/L) 5.90 25.70 76.50
%CV 4.5 4.2 4.2


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (μmol/L) 5.90 25.70 76.50
%CV 6.8 7.2 7.3


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 101%.

Parameters Standard 1 Standard 2 Standard 3
Expected Conc. (μmol/L) 8.4 32.5 67.5
Observed Conc. (μmol/L) 8.5 32.0 69.7
Recovery rate (%) 101 98.5 103.2


Sensitivity

The analytical sensitivity of the assay is 0.85 μmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.


Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration
(μmol/L)
0 0.5 1 2 4 6 8 10
Average OD 0.045 0.064 0.085 0.126 0.206 0.287 0.361 0.434
Absoluted OD 0 0.019 0.041 0.081 0.161 0.242 0.316 0.390