Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Total Antioxidant Capacity (T-AOC) Colorimetric Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Total Antioxidant Capacity (T-AOC) Colorimetric Assay Kit (ABTS, Chemical Method)

SKU: E-BC-K271-M-500

  • £32500
  • Save £5700


Total Antioxidant Capacity (T-AOC) Colorimetric Assay Kit (ABTS, Chemical Method)

SKU # E-BC-K271-M
Detection Instrument Microplate reader (730-740 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms T-AOC
Sample type Serum, plasma, urine, saliva, tissue, cells
Sensitivity 0.05 mmol/L
Detection range 0.05-1.00 mmol/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 20 min
Precision Average inter-assay CV: 5% | Average intra-assay CV: 4.100%
Other instruments required Micropipettor, Centrifuge, Vortex mixer
Other reagents required Double distilled water, 1 × PBS, 80% Ethanol
Storage -20℃
Valid period 12 months

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.05-1.00 mmol/L).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
20% Tomato tissue homogenization 2-5
10% Mouse heart tissue homogenization 8-12
10% Mouse liver tissue homogenization 8-12
10% Mouse lung tissue homogenization 8-12
Human saliva 2-5
Human urine 15-30
Human serum 15-30
Human plasma 8-15

 

Note: The diluent is 1 × PBS or 80% ethanol.

 

Detection Principle

The principle of the ABTS method for determining the T-AOC is as follows. ABTS is oxidized to green ABTS+ by appropriate oxidant, which can be inhibited if there exist antioxidants. The T-AOC of the sample can be determined and calculated by measuring the absorbance of ABTS+ at 734 nm. Trolox is an analog of VE and has a similar antioxidant capacity to that of VE. Trolox is used as a reference for other antioxidant antioxidants. For example, the T-AOC of Trolox is 1, then the antioxidant capacity of the other substance with the same concentration is showed by the ratio of its antioxidant capacity to Trolox antioxidant capacity.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 ABTS Solution 0.3 mL × 1 vial 0.6 mL × 1 vial -20°C, 12 months
shading light
Reagent 2 Oxidant Solution 0.3 mL × 1 vial 0.6 mL × 1 vial -20°C, 12 months
Reagent 3 5 mmol/L Trolox Standard 0.5 mL × 1 vial 0.5 mL × 1 vial -20°C, 12 months
shading light
Reagent 4 10×PBS Solution 1.5 mL × 1 vial 1.5 mL × 2 vials -20°C, 12 months
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.25 0.45 0.76
%CV 4.5 4.1 3.7


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.25 0.45 0.76
%CV 4.7 4.9 5.4


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 102%.

Parameters Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.2 0.55 0.85
Observed Conc. (mmol/L) 0.2 0.5 0.9
Recovery rate (%) 101 99 106


Sensitivity

The analytical sensitivity of the assay is 0.05 mmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mmol/L) 0 0.15 0.3 0.45 0.6 0.75 0.9 1
Average OD 0.953 0.810 0.690 0.574 0.472 0.325 0.231 0.135
Absoluted OD 0 0.143 0.263 0.379 0.481 0.628 0.722 0.818