Acid Phosphatase (ACP) Activity Assay Kit

SKU: E-BC-K094-S-500

  • £18800
  • Save £3200



Acid Phosphatase (ACP) Activity Assay Kit

SKU # E-BC-K094-S
Detection Instrument Spectrophotometer (520 nm)
Detection Method Colorimetric method


Product Details

Properties

Synonyms ACP
Sample Type Serum, plasma, urine, tissue, cells
Sensitivity 0.27 U/100 mL
Detection Range 0.27-40 U/100 mL
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 70 min
Precision Average inter-assay CV: 7.100% | Average intra-assay CV: 2.800%
Other instruments required Micropipettor, Incubator, Vortex mixer, Centrifuge
Other reagents required Normal saline (0.9% NaCl), PBS (0.01 M, pH 7.4)
Storage 2-8℃
Valid period 12 months

 

Dilution of Sample

It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.27-40 U/100 mL).

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
Human milk 1
Human saliva 1
Human urine 1
Human serum 1
HepG2 cells homogenization 2-8
10% Mouse kidney tissue homogenization 8-12
10% Mouse liver tissue homogenization 8-12
10% Mouse spleen tissue homogenization 8-12

 

Note: The diluent is normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4).

 

Detection Principle

Acid phosphatase decomposes disodium phenyl phosphate under acidic conditions to produce free phenol and phosphoric acid. Phenol acts with 4-aminoantipyrine in alkaline solution, and oxidizes to a derivative of red quinone by potassium ferricyanide. The activity of the ACP can be calculated by measuring the OD value at 520 nm.

 

Kit Components & Storage

Item Component Size (100 Assays) Storage
Reagent 1 Buffer Solution 60 mL ×1 vial 2-8℃, 12 months
Reagent 2 Substrate Solution 60 mL × 1 vial 2-8℃, 12 month shading light
Reagent 3 Alkali Reagent 60 mL × 2 vials 2-8℃, 12 month shading light
Reagent 4 Chromogenic Agent 60 mL × 3 vials 2-8℃, 12 month shading light
Reagent 5 1.0 mg/mL Phenol Standard 1 mL × 1 vial 2-8℃, 12 month shading light


Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (U/100 mL) 2.80 16.50 32.40
%CV 2.9 2.6 2.9


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/100 mL) 2.80 16.50 32.40
%CV 7.0 6.9 7.4

 

Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 100%.


Sample 1 Sample 2 Sample 3
Expected Conc. (U/100 mL) 10.8 22.5 35.5
Observed Conc. (U/100 mL) 10.7 22.1 36.6
Recovery rate (%) 99 98 103


Sensitivity

The analytical sensitivity of the assay is 0.27 U/100 mL. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (mg/mL) 0 0.1 0.2 0.4 0.6 0.8 1
Average OD 0.018 0.206 0.396 0.772 1.110 1.491 1.817
Absoluted OD 0 0.188 0.378 0.754 1.092 1.473 1.799