Thank you!

Your quote has been successfully submitted!

For products requiring additional information, our team will contact you within 1 business day

Failed

There was an error submitting your quote. Please try again.

Aldehyde Dehydrogenase (ALDH) Activity Assay Kit– MSE Supplies LLC

Free Shipping on MSE PRO Online Orders of $500 or More! U.S. Orders Only * Offer Excludes Hazmat Shipments *

Menu

This product has been added to the cart.

Aldehyde Dehydrogenase (ALDH) Activity Assay Kit

SKU: E-BC-K565-M-96

  • £30000
  • Save £5400



Aldehyde Dehydrogenase (ALDH) Activity Assay Kit

SKU # E-BC-K565-M
Detection Instrument Microplate reader (440-460 nm, optimum wavelength: 450 nm)
Detection method Colorimetric method


Product Details

Properties

Synonyms ALDH
Sample type Serum (plasma), animal tissue
Sensitivity 0.01 U/L
Detection range 0.01–10.0 U/L
Detection Method Colorimetric method
Assay type Enzyme Activity
Assay time 80 min
Precision Average inter-assay CV: 7.300% | Average intra-assay CV: 3%
Other instruments required Incubator, Centrifuge
Storage -20℃
Valid period 12 months


Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Rat kidney tissue homogenate 4-8
10% Mouse kidney tissue homogenate 4-8
10% Mouse liver tissue homogenate 4-8
10% Mouse lung tissue homogenate 4-8
Mouse serum 4-8
Rat serum 4-8
Human serum 4-8
Rat plasma 4-8

 

Note: The diluent is normal saline (0.9% NaCl). For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Detection Principle

The detection principle of this kit is that the substrate under the action of aldehyde dehydrogenase transforms NAD+ into NADH, which under the action of electron coupling agent, transfer electrons to WST-8 to produce the yellow product. The activity of ADH can be calculated by measuring the change of absorbance value at 450 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Buffer Solution 9 mL × 1 vial 18 mL × 1 vial -20°C, 12 months
Reagent 2 Coenzyme Powder × 1 vial Powder × 2 vials -20°C, 12 months shading light
Reagent 3 Substrate 0.08 mL × 1 vial 0.08 mL × 1 vial -20°C, 12 months shading light
Reagent 4 Chromogenic Agent 1.2 mL×1 vial 1.2 mL×2 vials -20°C, 12 months shading light
Reagent 5 Standard Powder × 1 vial Powder × 2 vial -20°C, 12 months shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay. (CV = Coefficient of Variation)

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 0.56 2.7 8.50
%CV 3.5 3.0 2.5


Inter-assay Precision

Three human serum samples were assayed 17 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 0.56 2.7 8.50
%CV 6.8 7.5 7.6


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 99%.


Standard 1 Standard 2 Standard 3
Expected Conc. (μmol/L) 135 264 425
Observed Conc. (μmol/L) 136.4 253.4 425.0
Recovery rate (%) 101 96 100

 

Sensitivity

The analytical sensitivity of the assay is 0.01 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (μmol/L) 0 100 150 200 300 400 450 500
OD value 0.056 0.184 0.253 0.333 0.459 0.576 0.633 0.708
0.052 0.188 0.5 0.323 0.432 0.564 0.633 0.703
Average OD 0.054 0.186 0.252 0.328 0.446 0.570 0.633 0.706
Absoluted OD 0.000 0.132 0.198 0.274 0.392 0.516 0.579 0.652