D-Xylose Colorimetric Assay Kit

SKU: E-BC-K018-S-100

  • £13100
  • Save £2300


D-Xylose Colorimetric Assay Kit

SKU # E-BC-K018-S
Detection Instrument Spectrophotometer(554 nm)
Detection Method Colorimetric method


Product Details

Properties

Synonyms D-aldopentose
Sample Type Serum, plasma, urine
Sensitivity 0.007 mmol/L
Detection Range 0.007-4 mmol/L
Detection Method Colorimetric method
Assay type Quantitative
Assay time 30 min
Precision Average inter-assay CV: 4.500% | Average intra-assay CV: 2.200%
Other instruments required Micropipettor, Vortex mixer, Water bath
Other reagents required Normal saline (0.9% NaCl) or PBS (0.01 M, pH 7.4)
Storage 2-8℃
Valid period 12 months

 

Detection Principle

D-xylose can produce furfural by dehydration in strong acid solution. The generated furfural reacts with Phloroglucinol to form pink compounds. The content of D-xylose can be calculated by colorimetric assay at 554 nm.

 

Kit Components & Storage

Item Component Size 1
(50 assays)
Size 2
(100 assays)
Storage
Reagent 1 Phloroglucinol 60 mL × 3 vials 60 mL × 6 vials 2-8℃, 12 months shading light
Reagent 2 13.3 mmol/L D-Xylose Standard 1 mL × 1 vial 1 mL × 1 vial 2-8℃, 12 months
Reagent 3 Standard Diluent 10 mL × 1 vial 10 mL × 1 vial 2 2-8℃, 12 months

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.05 1.20 3.50
%CV 2.5 2.0 2.1


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.05 1.20 3.50
%CV 4.3 4.8 4.4


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 103%.


Sample 1 Sample 2 Sample 3
Expected Conc. (mmol/L) 0.1 1.5 3
Observed Conc. (mmol/L) 0.1 1.5 3.2
Recovery rate (%) 104 100 105


Sensitivity

The analytical sensitivity of the assay is 0.007 mmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.