L-Arginine (L-Arg) Colorimetric Assay Kit

SKU: E-BC-K850-M-96

  • £31200
  • Save £5500



L-Arginine (L-Arg) Colorimetric Assay Kit

SKU # E-BC-K850-M
Detection Instrument Microplate reader (510-530 nm, optimum wavelength: 520 nm)
Detection method: Colorimetric method


Product Details

Properties

Synonyms L-Arg
Sample type Serum, plasma, urine, plant and animal tissue
Sensitivity 0.008 mmol/L
Detection range 0.008-1 mmol/L
Detection method Colorimetric method
Assay type Quantitative
Precision Average inter-assay CV: 6-8% | Average intra-assay CV: 1.8-3.8%
Other instruments required 60℃ and 100℃ water bath, 10 KD ultrafiltration tube
Other reagents required Normal saline (0.9% NaCl)
Storage -20℃
Valid period 12 months


Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Rat liver tissue homogenate 1-2
10% Rat kidney tissue homogenate 1-2
10% Rat heart tissue homogenate 1-2
10% Rat lung tissue homogenate 1-2
Human serum 1-2
Human plasma 1-2
Bovine serum 1-2
10% Nartjie tissue homogenate 1-2


Note: The diluent is buffer solution A. For the dilution of other sample types, please do pretest to confirm the dilution factor.

 

Detection Principle

Arginine (Arg) is an essential amino acid in the human body and can also be absorbed in food. Natural arginine is L-type, which is alkaline and easily reacts with acids to form salts. Arginine is an intermediate metabolite in the ornithine cycle, which can promote the conversion of ammonia into urea, thereby reducing blood ammonia content.Arginine generates urea under the action of enzymes, and urea can complex with oxime reagents under strong acidic conditions by boiling. The complex has a maximum absorption peak at 520 nm, and the arginine content can be calculated by measuring the OD value at 450 nm.

 

Kit Components & Storage

Item Component Size (96 T) Storage
Reagent 1 Buffer Solution A 50 mL × 1 vial -20℃, 12 months
Reagent 2 Buffer Solution B 1.8 mL × 1 vial -20℃, 12 months, shading light
Reagent 3 Enzyme Reagent A Powder ×2 vials -20℃, 12 months, shading light
Reagent 4 Enzyme Reagent B Powder ×2 vials -20℃, 12 months, shading light
Reagent 5 Chromogenic Agent A 24 mL ×1 vial -20℃, 12 months, shading light
Reagent 6 Chromogenic Agent B 24 mL ×1 vial -20℃, 12 months, shading light
Reagent 7 1 mmol/L Standard 1 mL ×2 vials -20℃, 12 months, shading light

Microplate 96 wells No requirement

Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three human serum samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.05 0.32 0.74
%CV 3.8 1.9 1.8


Inter-assay Precision

Three human serum samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (mmol/L) 0.05 0.32 0.74
%CV 8.0 6.0 7.6


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 96%.


Standard 1 Standard 2 Standard 3
Expected Conc. (mmol/L) 0.15 0.42 0.7
Observed Conc. (mmol/L) 0.1 0.4 0.7
Recovery rate(%) 98 94 96

 

Sensitivity

The analytical sensitivity of the assay is 0.008 mmol/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.

 

Standard Curve

As the OD value of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique or temperature effects), so the standard curve and data are provided as below for reference only:

Concentration (μg/mL) 0 0.1 0.2 0.3 0.5 0.6 0.8 1.0
OD Value 0.064 0.115 0.173 0.224 0.330 0.370 0.464 0.579
0.064 0.115 0.173 0.224 0.328 0.370 0.471 0.584
Average OD 0.064 0.115 0.173 0.224 0.329 0.370 0.468 0.582
Absoluted OD 0 0.051 0.109 0.160 0.265 0.306 0.404 0.518