NADH Oxidase (NOX) Activity Assay Kit

SKU: E-BC-K806-M-96

  • £29500
  • Save £5200



NADH Oxidase (NOX) Activity Assay Kit

SKU # E-BC-K806-M
Detection Instrument Microplate reader (590-610 nm, optimum wavelength: 600 nm)
Detection method: Colorimetric method


Product Details

Properties

Synonyms NOX
Sample type Plant, animal tissue and cell samples
Sensitivity 0.38 U/L
Detection range 0.38-22.09 U/L
Detection method Colorimetric method
Assay type Enzyme Activity
Assay time 15 min
Precision Average inter-assay CV: 7.100% | Average intra-assay CV: 4%
Other instruments required Centrifuge
Storage -20℃
Valid period 12 months


Dilution of Sample

The recommended dilution factor for different samples is as follows (for reference only):

Sample type Dilution factor
10% Mouse liver tissue homogenate 5-10
10% Mouse heart tissue homogenate 2-3
10% Porcine heart tissue homogenate 1-3
10% Rat brain tissue homogenate 1
10% Mouse kidney tissue homogenate 3-5
10% Mouse muscle tissue homogenate 1
10% Bovine liver tissue homogenate 5-8
10%Epipremnum aureum tissue homogenate 1

 

Note: The diluent is extraction solution B. For the dilution of other sample types, please do pretest to confirm the dilution factor

 

Detection Principle

NADH Oxidase(NOX)is widely found in the animals, plants, microorganisms and cultured cells, which can directly oxidize NADH to NAD+ in the presence of oxygen, and reduce blue DCPIP to colorless DCPIP. The activity of NOX can be calculated by measuring the reduction rate of blue DCPIP at 600 nm.

 

Kit Components & Storage

Item Component Size 1(48 T) Size 2(96 T) Storage
Reagent 1 Extraction Solution A 50 mL × 1 vial 50 mL × 2 vials -20℃, 12 months
Reagent 2 Extraction Solution B 15 mL × 1 vial 30 mL × 1 vial -20℃, 12 months
Reagent 3 Inhibitor 0.8 mL × 1 vial 0.8 mL × 2 vials -20℃, 12 months, shading light
Reagent 4 Buffer Solution 10 mL×1 vial 20 mL ×1 vial -20℃, 12 months
Reagent 5 Substrate A 1.2 mL×1 vial 1.2 mL ×2 vials -20℃, 12 months, shading light
Reagent 6 Substrate B Powder × 1 vial Powder ×2 vials -20℃, 12 months, shading light
Microplate 96 wells No requirement
Plate Sealer 2 pieces

 

Note: The reagents must be stored strictly according to the preservation conditions in the above table. The reagents in different kits cannot be mixed with each other. For a small volume of reagents, please centrifuge before use, so as not to obtain sufficient amount of reagents.

 

Technical Data:

Parameter:

Intra-assay Precision

Three mouse heart tissue samples were assayed in replicates of 20 to determine precision within an assay (CV = Coefficient of Variation).

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 2.60 13.50 18.40
%CV 4.3 4.0 3.7


Inter-assay Precision

Three mouse heart tissue samples were assayed 20 times in duplicate by three operators to determine precision between assays.

Parameters Sample 1 Sample 2 Sample 3
Mean (U/L) 2.60 13.50 18.40
%CV 6.8 7.0 7.5


Recovery

Take three samples of high concentration, middle concentration and low concentration to test the samples of each concentration for 6 times parallelly to get the average recovery rate of 102%.


Sample 1 Sample 2 Sample 3
Expected Conc. (U/L) 5.2 10.8 16.5
Observed Conc. (U/L) 5.1 11.1 17.2
Recovery rate(%) 99 103 104

 

Sensitivity

The analytical sensitivity of the assay is 0.38 U/L. This was determined by adding two standard deviations to the mean O.D. obtained when the zero standard was assayed 20 times, and calculating the corresponding concentration.