RADWAG MA 5Y Moisture Analyzers
SKU: WL-304-0046
RADWAG MA 5Y Moisture Analyzers
Buy RADWAG products from MSE Supplies at the best value.
SKU # |
WL-304-0046 |
WL-304-0037 |
WL-304-0043 |
WL-304-0034 |
WL-304-0040 |
WL-304-0048 |
WL-304-0039 |
WL-304-0045 |
Model # |
MA 50/1.5Y |
MA 200/1.5Y |
MA 50.5Y |
MA 110.5Y |
MA 210.5Y |
MA 50/1.5Y.WH |
MA 200/1.5Y.WH |
MA 50.5Y.WH |
Maximum Capacity (g) |
50 |
200 |
50 |
110 |
210 |
50 |
200 |
50 |
Readability (mg) |
0.1 |
0.1 |
1 |
1 |
1 |
0.1 |
0.1 |
1 |
SKU # |
WL-304-0036 |
WL-304-0042 |
WL-304-0047 |
WL-304-0038 |
WL-304-0044 |
WL-304-0035 |
WL-304-0041 |
Model # |
MA 110.5Y.WH |
MA 210.5Y.WH |
MA 50/1.5Y.NS |
MA 200/1.5Y.NS |
MA 50.5Y.NS |
MA 110.5Y.NS |
MA 210.5Y.NS |
Maximum Capacity (g) |
110 |
210 |
50 |
200 |
50 |
110 |
210 |
Readability (mg) |
1 |
1 |
0.1 |
0.1 |
1 |
1 |
1 |
It Dries in 4 Ways
-
The MA 5Y Moisture Analyzer offers you four drying profiles: standard, mild, fast and step
-
The standard profile is the usually used drying profile. It allows the most accurate determination of moisture content.
-
The mild profile is designed for drying substances that are sensitive to the rapid heat released by the filaments, which heat full power at the initial stage of the process. An example of such a substance is leather.
-
You will use the fast profile for samples with significant moisture content – of the order of even several tens of percent.
- The step profile will be ideal for drying substances that contain more than 15 percent moisture. Within this profile you can define any three temperatures. You will choose the values of temperature and duration of heating experimentally.
What Drying Temperature Should I Set?
The drying temperature determines the duration of the process. Its value depends on the type of material. If the temperature is too low, it will under-dry the sample and, consequently, unnecessarily increase the measurement time, while if it is too high, it will cause a burning effect on the material. The drying temperature for the traditional (oven) method is determined by industry or factory standards. If there are no standards, you will select the temperature experimentally.
The maximum drying temperature on the MA 5Y Moisture Analyzer is 160°C.
How Do I Finish the Drying? In 4 Ways
The MA 5Y Moisture Analyzer has four finish modes: automatic, manual, time-defined and user-defined.
-
Automatic mode
You define the moisture loss limit value in 60 seconds. When the moisture analyzer reaches the set criterion, the measurement will automatically end.
-
Manual mode
You terminate the measurement yourself by pressing the STOP button.
-
Time-defined mode
The measurement ends after the set time has elapsed regardless of the result. You have up to 99 hours 59 minutes to manage!
-
User-defined mode
When you remove all volatiles from a sample, by definition, its mass should be constant. During drying, the dry mass of the sample is defined by a condition: if the mass of the sample is stable within 1 mg during the observation time (Auto 1-5), we consider that all volatile components have been removed from its structure.
Digital Weighing Auditor
Ensures that your moisture analyzer is ready for use. What is more, it informs about the need for a moisture analyzer inspection or a periodic audit of the moisture analyzer’s accuracy and sensitivity.
10-Inch Display
Bigger screen – 10’’ – means more information in one place. On the new ELLIPSIS terminal, you will see up to 3 screens, widgets, graphs, statuses, notes, handy measurement history.
Uncompromising User Verification
For the first time ever, the moisture analyzer will verify the user using a password, RFID card, fingerprint reader, facial recognition mechanism, or any combination of these.
Ambient Light – an Innovative Way for the Moisture Analyzer to Communicate With the User
The light colour will tell you about status, process results, procedures, or alerts.
Hotspot
Use the moisture analyzer on any device connected to it. This can be a smartphone, tablet, or computer.
RFID
ELLIPSIS works with RFID tags* that can be used to tag your products or formulation ingredients in the database. They can also be used to identify a user.
Live Note – Note Down Your Conclusions
It’s the first time you can add a voice memo to a measurement series or procedure report. If you prefer to write it down, ELLIPSIS allows you to add a text note.
Handy Library
This is where a series of recent measurements or a report ready for digital signature, according to 21 CFR Part 11, can be found.
Widgets
Prepared to display what you need most at any given moment.
21 CFR Part 11
Do you work in the pharmaceutical industry? Do you need a digital signature?
- Full data security
- Electronic signatures
- Validations
- Electronic records
- Audit trails
Modbus TCP/IP
is one of the most popular communication protocols in industrial automation. Implementing it in the 5Y balances and CY10 scales makes the devices of this series friendly to automation integrator.
A balance or scale in a Modbus system is a slave device and performs tasks specified by the master device which is most often a PLC. Protocol Modbus TCP/IP in the 5Y balances and C10 scales enables, among other things, the realization of mass readout, zeroing and tare functions of the device, as well as tare settings and MIN and MAX thresholds.
Datasheet
Model No. |
MA 50/1.5Y |
MA 200/1.5Y |
MA 50.5Y |
MA 110.5Y |
MA 210.5Y |
MA 50/1.5Y.WH |
MA 200/1.5Y.WH |
MA 50.5Y.WH |
Metrological parameters |
||||||||
Maximum capacity [Max] |
50 g |
200 g |
50 g |
110 g |
210 g |
50 g |
200 g |
50 g |
Readability [d] |
0.1 mg |
0.1 mg |
1 mg |
1 mg |
1 mg |
0.1 mg |
0.1 mg |
1 mg |
Tare range |
-50 g |
-200 g |
-50 g |
-110 g |
-210 g |
-50 g |
-200 g |
-50 g |
Adjustment |
external |
|||||||
Maximum sample weight |
50 g |
200 g |
50 g |
110 g |
210 g |
50 g |
200 g |
50 g |
Heating module |
IR emitter |
halogen |
IR emitter |
halogen |
||||
Moisture content repeatability |
+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g) |
|||||||
Moisture content readability |
0.0001% |
0.0001% |
0.001% |
0.001% |
0.001% |
0.0001% |
0.0001% |
0.001% |
Drying temperature range |
Max 160 °C |
Max 250 °C |
Max 160 °C |
Max 250 °C |
||||
Physical parameters |
||||||||
Leveling system |
semi-automatic - LevelSENSING |
|||||||
Display |
10″ graphic colour touchscreen |
|||||||
Weighing chamber |
automatic |
|||||||
Maximum sample height |
20 mm |
|||||||
Weighing pan dimensions |
ø90, h= 8 mm |
|||||||
Packaging dimensions |
540×610×470 mm |
|||||||
Net weight |
5.3 kg |
5.3 kg |
5.3 kg |
5.3 kg |
5.4 kg |
5.3 kg |
5.3 kg |
5.3 kg |
Gross weight |
6.8 kg |
6.8 kg |
13 kg |
6.8 kg |
6.9 kg |
6.8 kg |
6.8 kg |
6.8 kg |
Construction |
||||||||
Protection class |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
Features of use |
||||||||
Display mode |
%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC |
|||||||
Drying method |
4 drying profiles (standard, fast, step, mild) |
|||||||
Finish mode |
4 modes (automatic, manual, time-defined, user-defined) |
|||||||
Additional functions |
sample traceability |
|||||||
Communication interface |
||||||||
Communication interface |
2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot |
|||||||
Electrical parameters |
||||||||
Power supply |
100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz |
|||||||
Power consumption |
6 W |
|||||||
Heating module power |
450 W |
|||||||
Environmental conditions |
||||||||
Operating temperature |
+10 — +40 °C |
|||||||
SOP – metrological tests |
||||||||
Mass indication control |
External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer) |
|||||||
Internal adjustment |
For .IC models only, GLP report |
|||||||
External adjustment |
For all models, GLP report |
|||||||
Drying temperature control |
One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer) |
|||||||
Moisture content indication control |
Certified MV Test Set |
|||||||
Adjustment |
||||||||
Internal / External adjustment |
Depending on the type of moisture analyzer, GLP report |
|||||||
Drying temperature adjustment |
Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer) |
Model No. |
MA 50/1.5Y |
MA 200/1.5Y |
MA 50.5Y |
MA 110.5Y |
MA 210.5Y |
MA 50/1.5Y.WH |
MA 200/1.5Y.WH |
Metrological parameters |
|||||||
Maximum capacity [Max] |
50 g |
200 g |
50 g |
110 g |
210 g |
50 g |
200 g |
Readability [d] |
0.1 mg |
0.1 mg |
1 mg |
1 mg |
1 mg |
0.1 mg |
0.1 mg |
Tare range |
-50 g |
-200 g |
-50 g |
-110 g |
-210 g |
-50 g |
-200 g |
Adjustment |
external |
external |
external |
external |
external |
external |
external |
Maximum sample weight |
50 g |
200 g |
50 g |
110 g |
210 g |
50 g |
200 g |
Heating module |
IR emitter |
halogen |
IR emitter |
halogen |
|||
Moisture content repeatability |
+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g) |
||||||
Moisture content readability |
0.0001% |
0.0001% |
0.001% |
0.001% |
0.001% |
0.0001% |
0.0001% |
Drying temperature range |
Max 160 °C |
Max 250 °C |
Max 160 °C |
Max 250 °C |
|||
Physical parameters |
|||||||
Leveling system |
semi-automatic - LevelSENSING |
||||||
Display |
10″ graphic colour touchscreen |
||||||
Weighing chamber |
automatic |
||||||
Maximum sample height |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
20 mm |
Weighing pan dimensions |
ø90, h= 8 mm |
||||||
Packaging dimensions |
540×610×470 mm |
||||||
Net weight |
5.3 kg |
5.3 kg |
5.3 kg |
5.3 kg |
5.4 kg |
5.3 kg |
5.3 kg |
Gross weight |
6.8 kg |
6.8 kg |
13 kg |
6.8 kg |
6.9 kg |
7 kg |
6.8 kg |
Construction |
|||||||
Protection class |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
IP 43 |
Features of use |
|||||||
Display mode |
%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC |
||||||
Drying method |
4 drying profiles (standard, fast, step, mild) |
||||||
Finish mode |
4 modes (automatic, manual, time-defined, user-defined) |
||||||
Additional functions |
sample traceability |
||||||
Communication interface |
|||||||
Communication interface |
2×USB-A, USB-C, HDMI, Ethernet, Wi-Fi®, Hotspot |
||||||
Electrical parameters |
|||||||
Power supply |
100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz |
||||||
Power consumption |
6 W |
||||||
Heating module power |
450 W |
||||||
Environmental conditions |
|||||||
Operating temperature |
+10 — +40 °C |
||||||
SOP – metrological tests |
|||||||
Mass indication control |
External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer) |
||||||
Internal adjustment |
For .IC models only, GLP report |
||||||
External adjustment |
For all models, GLP report |
||||||
Drying temperature control |
One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer) |
||||||
Moisture content indication control |
Certified MV Test Set |
||||||
Adjustment |
|||||||
Internal / External adjustment |
Depending on the type of moisture analyzer, GLP report |
||||||
Drying temperature adjustment |
Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer) |
*The power supply can be connected to the socket on the back of the balance housing or to the terminal.
MSE Supplies is an authorized distributor for RADWAG.