RADWAG MA R Moisture Analyzers

RADWAG MA R Moisture Analyzers

SKU: WL-305-00025

  • £1,52900
  • Save £26900



RADWAG MA R Moisture Analyzers

Buy RADWAG products from MSE Supplies at the best value.

Sku #

WL-305-0002

WL-305-0001

WL-305-0004

WL-305-0003

WL-305-0006

WL-305-0005

Model #

MA 50/1.R

MA 50.R

MA 110.R

MA 210.R

MA 50/1.R.WH

MA 50.R.WH

Maximum capacity(g)

50 g

50 g

110

210

210

50

Readability(mg)

0.1

1

1

1

1

1

 

Sku #

WL-305-0007

WL-305-0008

WL-305-0039

WL-305-0014

WL-305-0024

WL-305-0009

Model #

MA 110.R.WH 

MA 210.R.WH

MA 50/1.R.NS

MA 50.R.NS

MA 110.R.NS 

MA 210.R.NS

Maximum capacity(kg)

110

210

50

50

110

210

Readability(g)

1

1

0.1

1

1

1

 

MA 50/1.R Moisture Analyzer

Moisture analyzer is a laboratory measuring instrument intended to determine relative humidity for small samples of different materials. MA.R series redefines moisture analyzers standards.

The MA.R series

This series has been equipped with brand new readable LCD display providing an extra text line for information such as supplementary messages and data, e.g. product name or tare value 
The moisture analyzer, using respective pictograms, signalizes currently activated mode, computer connection and functions, both balance and service ones. 
The MA.R series is enriched with various interfaces: RS232, USB type A,
USB type B and Wi-Fi®. The moisture analyzer is housed in a plastic casing.

Databases:

Information system of R series moisture analyzers is based on 6 databases, allowing many operators to operate product database comprising many samples. Collected measurements may be subjected to subsequent analysis.

Collected data is registered in 6 databases:

  • Users (up to 10 users)
  • Products (up to 1000 products)
  • Weighings (up to 1000 weighings)
  • Tares (up to 100 tares)
  • Programs (up to 100 drying programs)
  • Drying process reports (up to 1000 reports)

The results

The results obtained using the moisture analyzer (the final result of the drying process):

  • % M – the mass loss in %; displays the mass change recorded during the drying process, expressed as a percentage,
  • % D – the dry mass obtained during the drying process, expressed as a percentage; the result is the portion of the sample that remains on the weighing pan after the moisture has evaporated,
  • % R – the ratio of moisture content to dry mass, obtained during the drying process, expressed as a percentage; the result is the portion of the sample that evaporated during the drying process,
  • g – the sample mass after drying.

Exchange of information within the system is performed by means of USB port on bi-directional basis. It is possible to import and export databases using memory sticks.

Direct access to information

It is possible to access functions and databases directly, using keyboard soft keys.

  • Database – access to databases
  • Function – access to basic functions
  • F1 and F2 – programmable function keys and menu navigation keys
  • Reports – access to database of drying process reports
  • Profile – access to parameters settings
  • Sample – access to products database

Datasheet

Model No.

MA 50/1.R

MA 50.R

MA 110.R

MA 210.R

MA 50/1.R.WH

MA 50.R.WH

Metrological parameters

Maximum capacity [Max]

50 g

50 g

110  g

210 g

50 g

50 g

Readability [d]

0.1 g

1 g

1 g

1 g

0.1 g

1 g

Tare range

-50 g

-50 g

-110 g

-210 g

-50 g

-50 g

Adjustment

 external

 external

 external

 external

 external

 external

Maximum sample weight

50 g

50 g

110 g

210 g

50 g

50 g

Heating module

IR emitter

halogen

halogen

Moisture content repeatability

+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)

Moisture content readability

0.0001%

0.001%

0.001%

0.001%

0.0001%

0.001%

Drying temperature range

Max 160 °C

Max 160 °C

Max 160 °C

Max 160 °C

Max 250 °C

Max 250 °C

Physical parameters

Leveling system

manual

manual

manual

manual

manual

manual

Display

LCD (backlit)

Maximum sample height

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Weighing pan dimensions

ø90, h= 8 mm

Packaging dimensions

476×381×346 mm

Net weight

4.8 kg

4.63 kg

4.8 kg

4.8 kg

4.8 kg

4.8 kg

Gross weight

6 kg

6 kg

6 kg

6 kg

6 kg

6 kg

Construction

Protection class

IP 43

IP 43

IP 43

IP 43

IP 43

IP 43

Features of use

Display mode

%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC

Drying method

4 drying profiles (standard, fast, step, mild)

Finish mode

4 modes (automatic, manual, time-defined, user-defined)

Additional functions

sample traceability

Communication interface

Communication interface

 RS232¹, USB-A, USB-B, Wi-Fi®

Electrical parameters

Power supply

 100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz

Power consumption

4 W

4 W

4 W

4 W

4 W

Heating module power

450 W

450 W

450 W

450 W

450 W

Environmental conditions

Operating temperature

+10 — +40 °C

SOP – metrological tests

Mass indication control

External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)

Internal adjustment

For .IC models only, GLP report

External adjustment

For all models, GLP report

Drying temperature control

One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer)

Moisture content indication control

Certified MV Test Set

Adjustment

Internal / External adjustment

Depending on the type of moisture analyzer, GLP report

Drying temperature adjustment

Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)

 

Model No.

MA 110.R.WH 

MA 210.R.WH

MA 50/1.R.NS

MA 50.R.NS

MA 110.R.NS 

MA 210.R.NS

Metrological parameters

Maximum capacity [Max]

110 g

210 g

50  g

50 g

110 g

210 g

Readability [d]

1 g

1 g

0.1 g

1 g

1 g

1 g

Tare range

-110 g

-210 g

-50 g

-50 g

-110 g

-210 g

Adjustment

 external

Maximum sample weight

110 g

210 g

50 g

50 g

50 g

210 g

Heating module

halogen

metal heater

Moisture content repeatability

+/-0.05% (sample ~ 2g), +/-0.01% (sample ~ 10g)

Moisture content readability

0.001%

0.001%

0.0001%

0.001%

0.001%

0.001%

Drying temperature range

Max 250 °C

Max 250 °C

Max 160 °C

Max 160 °C

Max 160 °C

Max 160 °C

Physical parameters

Leveling system

manual

manual

manual

manual

manual

manual

Display

LCD (backlit)

Maximum sample height

20 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Weighing pan dimensions

ø90, h= 8 mm

Packaging dimensions

476×381×346 mm

Net weight

4.8 kg

4.8 kg

4.8 kg

4.8 kg

4.8 kg

4.8 kg

Gross weight

5.5 kg

5.5 kg

5.5 kg

6.3 kg

6 3 kg

6 3 kg

Construction

Protection class

IP 43

IP 43

IP 43

IP 43

IP 43

IP 43

Features of use

Display mode

%MC, %DC, %ATRO MC, %ATRO DC, g, g/kg MC, g/kg DC, -%MC

Drying method

4 drying profiles (standard, fast, step, mild)

Finish mode

4 modes (automatic, manual, time-defined, user-defined)

Additional functions

sample traceability

Communication interface

Communication interface

 RS232¹, USB-A, USB-B, Wi-Fi®

Electrical parameters

Power supply

 100V – 120V AC 50/60Hz or 200V-240V AC 50/60Hz

Power consumption

4 W

4 W

4 W

4 W

4 W

Heating module power

450 W

450 W

450 W

450 W

450 W

Environmental conditions

Operating temperature

+10 — +40 °C

SOP – metrological tests

Mass indication control

External mass standard 50 g, 100 g, 200 g (depending on the type of moisture analyzer)

Internal adjustment

For .IC models only, GLP report

External adjustment

For all models, GLP report

Drying temperature control

One- or two-point, depending on the drying profile (equipment: GT105k-12/Z Control Thermometer)

Moisture content indication control

Certified MV Test Set

Adjustment

Internal / External adjustment

Depending on the type of moisture analyzer, GLP report

Drying temperature adjustment

Three-point adjustment at defined temperatures, programmable values (equipment: GT105k-12/Z Control Thermometer)



*The power supply can be connected to the socket on the back of the balance housing or to the terminal.